Discharge Pipe And Pressure Tank Connections; Pre-Charge Tank Connection; Standard Tank Connection; Connecting Discharge Piping - STA-RITE SN Serie Manual Del Propietário

Bombas tipo “jet” para pozos poco profundos
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Discharge Pipe and Pressure Tank Connections

PRE-CHARGE TANK CONNECTION

(FIGURE 4)
1. Install two tees in the pump discharge port (see
Figure 4). The pipe size must be at least as large as
the discharge port.
2. Run a pipe or reinforced hose from one arm of the
first tee to the port on the pre-charged tank.
3. Connect the other end of the discharge tee to your
plumbing system.
4. Check the pre-charge of air in the tank with an ordi-
nary tire gauge. The pre-charge should be 2 PSI less
than the cut-in setting of the pump's pressure switch.
The pre-charge is measured when there is no water
pressure in the tank. Your new pump has a 30/50 PSI
switch, so adjust the tank pre-charge pressure to
28 PSI.
Congratulations! You have just completed the tank
connection for your jet pump.
Please go to Page 8 for electrical hookup.
To Household
Water System
Pressure
Switch
2349 0396
Figure 4: Pre-charged Tank Connections
Use only Teflon tape or Teflon based joint compounds for making all threaded
connections to the pump itself. Do not use pipe joint compounds on plastic
pumps: they can react with the plastic in pump components. Make sure that all
pipe joints in the suction pipe are air tight as well as water tight. If the suction
pipe can suck air, the pump will not be able to pull water from the well.
Pump Priming
Tee and Plug
From Well
Check
Valve
Sealing Pipe Joints

STANDARD TANK CONNECTION

(FIGURE 5)
1. Install one tee in the pump discharge port
(see Figure 5).
2. Run a pipe from the pump discharge port to the inlet
port of your tank. The pipe size must be at least as
large as the discharge port.
3. Remove the 1/8" NPT pipe plug from the pump Air
Volume Control (AVC) port (see Figure 5). Run tubing
from the pump's AVC port (see Figure 5) to the port
on the AVC mounted on the tank. See instructions
provided with tank and AVC for details. AVC port
location will vary, depending on your pump model
(see exploded view, Page 11).
Congratulations! You have just completed the tank
connection for your jet pump.
Please go to Page 8 for electrical hookup.
To Household
Water System
Pump
Priming Tee
and Plug
Pressure
Switch
Figure 5: Standard Tank Connections
Air Volume
Control
Air Volume
Control Tube
2350 0396
From
Well
Check
Valve
6

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Hn serie