Wiring Connections; Connection Procedure - STA-RITE SN Serie Manual Del Propietário

Bombas tipo “jet” para pozos poco profundos
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Electrical

WIRING CONNECTIONS

Fire hazard. Incorrect voltage can cause a
fire or seriously damage the motor and voids the warran-
ty. The supply voltage must be within ±10% of the motor
nameplate voltage.
NOTICE: Dual-voltage motors are factory wired for 230
volts. If necessary, reconnect the motor for 115 volts, as
shown. Do not alter the wiring in single voltage motors.
Install, ground, wire, and maintain your pump in compli-
ance with the United States National Electrical Code (NEC)
or the Canadian Electrical Code (CEC), as applicable, and
with all local codes and ordinances that apply. Consult
your local building inspector for code information.

Connection Procedure:

1. Connect the ground wire first as shown in Figure 9.
The ground wire must be a solid copper wire at least
as large as the power supply wires.
WIRING CHART – RECOMMENDED WIRE AND FUSE SIZES
Max. Load
Motor HP
Volts
1/2
115/230
8.8/4.4
3/4
115/230
12.2/6.1
1
115/230
14.8/7.4
1-1/2
115/230
19.9/10.0
Branch Fuse
Amp
Rating Amp
15/15
14/14 (2/2)
20/15
12/14 (3/2)
20/15
12/14 (3/2)
25/15
10/14 (5.5/2)
2. There must be a solid metal connection between the
pressure switch and the motor for motor grounding
protection. If the pressure switch is not connected to
the motor, connect the green ground screw in the
switch to the green ground screw under the motor
end cover. Use a solid copper wire at least as large as
the power supply wires.
3. Connect the ground wire to a grounded lead in a ser-
vice panel, to a metal underground water pipe, to a
metal well casing at least ten feet (3M) long, or to a
ground electrode provided by the power company or
the hydro authority.
4. Connect the power supply wires to the pressure
switch as shown in Figure 9.
DISTANCE IN FEET(METERS) FROM MOTOR TO SUPPLY
0 - 100
101 - 200
(0 - 30)
(31 - 61)
AWG WIRE SIZE (mm
12/14 (3/2)
10/14 (5.5/2)
8/14 (8.4/2)
8/14 (8.4/2)
201 - 300
301 - 400
(62 - 91)
(92 - 122)
)
2
10/14 (5.5/2)
8/14 (8.4/2)
8/14 (8.4/2)
6/12 (14/3)
6/14 (14/2)
6/12 (14/3)
6/12 (14/3)
4/10 (21/5.5)
9
401 - 500
(123 - 152)
8/12 (8.4/3)
6/12 (14/3)
4/10 (21/5.5)
4/10 (21/5.5)

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Hn serie

Tabla de contenido