Preparing The Holes On The Machine; Fitting The Unit On The Bracket; Electric Hook-Up; Top/Bottom Installation Configuration - Olimpia splendid UNICO AIR 8 SF Instrucciones Para La Instalación, El Uso Y El Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

couple the two chains to the large eyelet of the spring.
-
Using one hand, grip the two chains connected to the grid.
-
Bend the external grids back, gripping them with your free hand where they bend, and insert your fingers inside the single
fins (fig. 13).
-
Insert your arm into the pipe until the grid protrudes completely outwards.
-
Reopen the grid, being careful to keep your fingers inside the fins.
-
Turn the grid until the fins are fully horizontal and tilted downwards.
-
Pull the chain, tensioning the spring, and couple the chain ring to the pin of the inner flange through which the pipes pass (fig.
14).
-
Use hand shears to cut off any excess chain links.
WARNING: use exclusively the supplied grids, or grids with like characteristics.
2.3.5

Preparing the holes on the machine

The unit was built to be paired with 162-mm.
2.3.6

Fitting the unit on the bracket

After having checked that the fixing bracket is properly anchored to the wall and that the suitable preparatory work - if required -
has been carried out for the electrical connections and the condensate drainage, the air-conditioner can be fixed to the wall. Lift it
by holding it from the sides of the lower base (see fig. 15).
To facilitate the operation of fastening it to the bracket, tilt it slightly toward you.
To make the electrical connection and fasten the drainpipe, place a wedge between the air conditioner and the wall (see fig. 15).
When you have finished, inspect carefully to make sure there are no fissures at the back of the air conditioner (the insulating gasket
must fit firmly against the wall) particularly in the zone where air enters and leaves the machine.
2.3.7

Electric hook-up

The appliance is fitted with a power cord with plug (Y-type connection). If the socket is in proximity to the appliance, simply plug it in.
Before connecting the conditioner, ensure that:
-
The power supply voltage and frequency values comply with those indicated on the data plate of the appliance.
-
The power supply line is fitted with an efficient earth connection that is appropriately sized for the maximum absorption
of the conditioner (minimum cross-section of the cable must be 1.5 mm
-
The appliance is powered exclusively through a socket that is compatible with the plug supplied.
WARNING: Any replacement of the power cable must be carried out solely by Olimpia Splendid technical support or by
similarly qualified personnel.
WARNING: On the power supply line of the appliance there must be an adequate omnipolar disconnection device that
complies with the national installation regulations. It is, however, necessary to check that the electrical power supply is
equipped with efficient earthing and with adequate protections against overloading and/or short circuits (a type 10 AT
delayed fuse or other devices with equivalent functions are recommended).
2.4

TOP/BOTTOM INSTALLATION CONFIGURATION

This unit may be installed either at the bottom of the wall (adjacent to the floor) or at the top (adjacent to the ceiling). The air jet
can be modified to optimize air distribution and room well-being by changing the position of the air outlet flap.
).
2
2
31
UNICO AIR

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Unico air 8 hpUnicoUnico air

Tabla de contenido