30
and set the value at 1. Vice versa if this value is set at 0 the option is disabled. The option is not
applicable to ½ turn spirals. If the payment system uses Executive protocol, the single-multivend must
also be set on the payment system.
•
Alternatively, the function can be enabled / disabled for each drawer: selection 91 implies that all the
selections in the first drawer from the top are, for example, enabled for the quarter turn function. Selection
92 = 2nd drawer; 93 = 3rd drawer; 94 = 4th drawer; 95 = 5th drawer; 96 = 6th drawer; 97 = 7th drawer; if
you program the function for selection 99, all the selections in the vending machine will be enabled or
disabled.
•
***At this point the machine proposes the enablement or disablement of the blank option (1 enabled, 0
disabled). This option functions in modes 0, 1 and 2 set previously; if enabled, when a product is not
dispensed ("not read by the photocell") the selection is considered empty and therefore no longer accessible.
To "restore" the selection on reloading, just open the main door of the machine so that the display visualises
"door open", then re-close the door.
E
The system then asks you to enter the options relevant to the PHOTOCELL SAFETY:
N
enabling this function (parameter setting = 1) involves entering a number of products within a certain time
G
frame (in minutes). If within the programmed time interval a number of non-readings occurs that is equal to
L
the number of programmed products, the photocells are disabled. The active event is signalled on the display
I
when the door is opened and it is also recorded in Command 99 by Error code 39. The photocell reset can be
S
programmed in manual or automatic mode. If manual, parameter setting = 0, enter the TEST VEND function
H
to re-enable the photocells; if automatic, parameter setting = 1, after 15 minutes the system attempts to reset
the function.
N.B.: with the SPIRAL SLAVE connection enabled (see Command 49), after setting the MASTER machine,
the same parameters for the SLAVE machine can be set.
Command 80 Cloning:
This command makes it possible to transfer all the parameters of the vending machine to a "Program Key",
to program same model machines (see also Command 50). When you enter the command "Write Clone
Key" appears on the display. Then, enter the "Program Key" and press the ENTER key. "Data Writing...*"
appears on the screen while the data is being transferred to the key. Once the data transfer operation is
completed, the machine returns to the programming mode.
Caution: DO NOT enter the key before entering the programming mode, otherwise the vending machine will
fetch the data existing in the key.
Command 81 Fetch vend data:
This command makes it possible to transfer all the EVA-DTS data to a "Program Key". This data can be
extracted using special software (VMC configurator). The maximum number of possible registrations is 100.
Attention: if the key is not recognised as a data key, at the first registration the user will be asked to confirm
the complete deletion of the existing data.
Command 85 Display of checksum and main and power board software version.
MEGACOLD L – Issue 01