MEGACOLD L– Issue 01
Time" appears on the display. At this point the vending machine will allow the sale of the products for the
amount of time set in Alarm 41.
This option is only available on MASTER vending machines.
Alarm 51 Weekly check daily inhibition vend point:
The command only functions if Alarms 01, 02 03 and 36 are set and the control is enabled, and concerns
both the master machine and any slaves connected to it. Up to 3 daily time slots can be set.
N.B.: The value 2400 set on "Start time slot 1" disables the function.
For partial daily inhibition, programme Alarm 36.
9.4

USE OF COINMECHANISM BDV 001

The coin mechanism must only be connected/disconnected with the machine
switched off.
After having carried out the connection, switch on the machine, enter the programming and set command 69
to 4, then switch off the machine for some seconds. By switching it on again the machine and the coin
mechanism will communicate correctly.
Purchase obligation before return
Command 30
Maximum credit
Command 31
Command 32
Maximum value of returned coins
Inhibition single coins
Command 33
Coin inhibition with exact amount
Command 34
Command 35
Coin level message exact amount
Equation exact amount
Command 36
Enabling credit card reader
Command 37
Command 38
Emptying of change giving tubes
Filling up of change giving tubes
Command 39
Command 30 Purchase obligation before return:
By setting this command to 1 the customer is obliged to purchase before receiving back the return. This is to
avoid to use the coin mechanism as a coin-changer. If the purchase fails to happen, the return will be given
out.
Command 31 Maximum credit:
The maximum credit accepted by the coin mechanism is set. By overtaking this value the acceptance of
further coins is blocked.
Command 32 Maximum value of returned coins:
This function is active only in multi-sale. If the value of the credit which remains after a sale is higher than the
value set by the command, the allotment of return will be blocked. Therefore it will be necessary to carry out
further purchases until the remaining credit will be lower than the set value. By moving the return lever it will
be possible to obtain the return.
Command 33 Inhibition single coins:
The acceptance of particular coins by the coin mechanism will be blocked through this command. If you want
to block the acceptance of coin 5, proceed as follows:
1. Programming mode, display views........................................................................................... Command 00
2. Dial 33 and press B, display views .............................................................................................. Coin no. 00
3. Dial 5 and press B, display views ................................................................................................................. 0
4. Dial 1 and press B.
(def. 0)
(def. 0)
(def. 0)
(all enabled)
(all enabled)
(def. 0)
(def. 0)
(def. 0)
35