40
10.1 SPIRALS
E
N
G
L
I
S
H
10.2 PROCEDURE FOR REPLACING SPIRALS AND EXPELLER MOTOR GROUP
10
Most of the products can be sold without problems when the end of the spiral is placed
on hour 6.
To modify the end, draw the spiral forward until the base of the spiral support will come
out from the pit; then turn the spiral in the wished position and put it again into the pit.
Each spiral can be turned each time of 45°.
CAUTION: when carrying out this operation ensure that the motor micro cam is always
in the standby position. To do this simply carry out several dispensing operations in the
"TEST VEND" mode (see paragraph FUNCTION/PROGRAMMING KEYBOARD).
The machine is supplied with trays with spirals of different diameters and pitches.
To vary their quantity or their order, proceed as follows:
•
Switch off the machine by means of the main switch and pull out the power plug.
•
Open the main door.
•
Pull out the tray on which you have to vary the spiral.
•
Switch off and take out the group motor-spiral.
•
Take out the spiral from the plastic support (lever between spiral and support) and
replace with the other spiral or with the other expeller motor group.
•
Fit up the new spiral group reversing the above operations. After having finished this
operation, make sure that the end of the spiral is put on hour 6, otherwise see
paragraph "SPIRALS".
ADJUSTMENTS
MEGACOLD L – Issue 01