E74
Motor 1 current level exceeded (Warning)
E75
Motor 2 current level exceeded (Warning)
E76
Liquid coolant flow level exceeded
(Warning)
E77
Coolant temperature level exceeded
(Warning)
E78
Active maintenance alarm
(Automation and robotics)
3.14 Rear panel
1
Off/On switch
Turns on the electric power to the welder.
It has two positions, "O" off, and "I" on.
2
Signal cable (CAN-BUS) input (RC)
3
Signal cable (CAN-BUS) input (Cable bundle)
4
Gas fitting (TIG)
5
Power supply cable
Connects the system to the mains.
3.15 Sockets panel
1
Negative power socket
For connection of earth cable in electrode welding or of
torch in TIG.
Allows the connection of the earth cable in MIG/MAG
and Pulsed MIG.
2
Positive power socket
For connection of electrode torch in MMA or earth
cable in TIG.
4 ACCESSORIES
4.1 General
Operation of the remote control is activated when connected
to the Selco power sources. This connection can be made also
with the system power on.
With the RC control connected, the power source control panel
stays enabled to perform any modification. The modifications
on the power source control panel are also shown on the RC
control and vice versa.
4.2 RC 100 remote control
The RC 100 is a remote control unit designed to manage the
display and the adjustment of the welding current and voltage.
"Consult the instruction manual".