System message
Functions that are still
available
Er44
Motor blocked
None
(The control system
attempted to start up the
motor three times - 5 times
per attempt)
Er55
More than 960 cleaning
Manual cleaning
−
cycles in 48 hours
−
Automatic mode
−
Time-dependent cleaning
Er66
Switch element for rinsing
None
pump in the control system
overheated
Possible cause
Remedy
Filter drum rotating sluggishly or
−
Clean edge of the drum/drum seal and grease edge of the
jammed
drum Only use original OASE grease (order number
27872).
−
Ensure that the rollers move smoothly
Remove larger particles (e.g. snails, stones) from the
−
sprocket
The lips of the drum seal were
Disassemble the drum and ensure that the drum seal is
−
squeezed when the drum was installed.
positioned correctly during re-assembly
The drum load is distributed unevenly
Align the container horizontally
−
Temporary heavy soiling
Wait until the soiling decreases
−
Start-up phase of the filter system
−
This operating status is atypical. Avoid long-term operation
(e.g. during the first start-up)
in this state.
Fish are spawning
−
Pond heavily soiled
−
Clean the pond
Reduce the amount of soiling
−
−
Install the filter pump in an elevated position.
Screen elements heavily soiled
Clean the screen elements, descale (→ Replacing screen
element)
Insufficient cleaning effect due to soiled
−
Clean nozzle
nozzle
Water level in the system too high:
−
Outlet pipes soiled
−
Clean outlet pipes
Outlet opening too small
Enlarge outlet opening
−
−
−
Max. flow rate exceeded
−
Reduce flow rate
−
A large amount of dirt has entered the
−
Clean the foam filters
filter system, water is flowing over
(instead of through) the foam filters.
Control system is exposed to excessive
Protect the control system from heat
heat (sun, ambient temperature)
- EN -
Resetting the system
message
On|Off
Press
key for 5 s
On|Off
Press
key for 5 s
−
Automatic if the number of
−
cleaning procedures drops
below 960.
Automatic when cooled down
47