Installation and connection

Important: If the planned installation deviates significantly from the recommendations contained in this
manual:
Have your specialist retailer check whether all technical specifications were adhered to. This is crucial
for a problem-free operation.
4.1

Installation planning

Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injuries caused by electric shock from electrical units
operated in or near water.
Protective measures for accessible ponds:
Only use electrical units or installations with a rated voltage of U
Electrical installations with a rated voltage of U
of at least 2 m from the water.
Protective measures for non-accessible ponds:
Electrical installations with a rated voltage of UAC > 12 V or UDC > 30 V must be located at a distance
of at least 2 m from the water.
Note:
Use suitable transport and lifting aids to transport and install the unit.
The unit weighs more than 25 kg (→ Technical Data).
Note!
The filter system operates day and night and causes rinsing noises during the automatic cleaning
cycles. (→ Technical data)
Please protect the general public and your neighbourhood from noise disturbance and comply with
the statutory noise regulations.
The filter system can be enclosed such that the enclosure effectively absorbs the noises.
Select the location of the filter system in order to avoid noise disturbance.
Plan the installation of the filter system. With careful planning, taking the ambient conditions into account,
you will obtain optimum operating results.
The following conditions must be met:
The filter system starts the cleaning cycles automatically - day and night. These cleaning cycles cause
noise emissions (→ Technical data).
As the filter module is very heavy when filled, it must be placed on a suitable base (at least on slabs,
but preferably on a poured concrete base) to prevent it from subsiding.
Horizontally align the base slab.
The filter system must be horizontally positioned (max. deviation d ± 5 mm).
Tip: Use commercially available concrete slabs, each measuring 500 × 500 mm. One concrete slab
is required for the operation of the filter system on its own; four concrete slabs are required for
operation of the filter system together with the ProfiClear Classic modules.
Plan sufficient space for carrying out cleaning and maintenance work.
Drain the dirty water into the drain or far enough away from the pond so that it cannot flow back into
the pond.
If the coarse soiling and dirty water both run into the same pipe, it is important to use at least DN
110 pipes.
Position the inlet in the pond (e.g. via a water course or waterfall) so that it is lower than the outlet of
the filter system.
Note:
A water course or waterfall guarantees optimum water return to the pond.
In this way, the filtered pond water is enriched with oxygen before it is returned to the pond.
≤ 12 V or U
AC
> 12 V or U
> 30 V must be located at a distance
AC
DC
- EN -
≤ 30 V in the water.
DC