BTL6-V1 _ E-M _ _ _ _ -A1-S115
Micropulse AT transducer in round profile housing
7
Technical data
7.1
Accuracy
The specifications are typical values at 24 V DC and room
temperature, with a nominal length of 500 mm in
conjunction with the BTL6-A-3800-2 or BTL6-A-3801-2
magnet.
The BTL is fully operational immediately, with full accuracy
after warm-up.
For special versions, other technical data may
apply. Special versions are indicated by the
suffix -SA on the part label.
Resolution
Repeat accuracy, typical
Sampling rate
Dependent on nominal length
At nominal lengths = 500 mm
(1 magnet)
Non-linearity at
Nominal length ≤ 500 mm
Nominal length > 500 mm
Temperature coefficient
(nominal length = 500 mm,
magnet in the center of the
measuring range)
7.2
Ambient conditions
Operating temperature
Storage temperature
Relative humidity
Shock rating
per EN 60068-2-27
1)
Continuous shock
per EN 60068-2-29
1)
Vibration
per EN 60068-2-6
1)
Degree of protection per
IEC 60529 (when attached)
12
english
< 10 µm
< 30 µm
500 µs to 3.5 ms
0.5 ms
±200 µm
±0.04 % FS
≤ 20 ppm/K
0°C to +70°C
−40°C to +100°C
< 90%, non-condensing
50 g/6 ms
50 g/2 ms
12 g, 10 to 2000 Hz
IP67
7.3
Supply voltage
Voltage, stabilized
2)
Ripple
Current draw
(at 24 V DC)
Inrush current
Reverse polarity protection
Overvoltage protection
Dielectric strength
(GND to housing)
7.4
Inputs/outputs
Short circuit resistance
7.5
Dimensions, weights
Housing diameter
Nominal length
Weight (depends on length) Approx. 1 kg/m
Housing material
Individual specifications as per Balluff factory standard
1)
For
: The transducer must be externally connected via a limited-
2)
energy circuit as defined in UL 61010-1, a low-power source as defined in
UL 60950-1, or a class 2 power supply as defined in UL 1310 or
UL 1585.
20 to 28 V DC
≤ 0.5 V
ss
≤ 100 mA
≤ 4 A/0.5 ms
Up to 36 V
Up to 36 V
(supply cables only!)
500 V DC
Signal cable to GND
30 mm
≤ 4012 mm
Anodized aluminum