ALARM IN SET : Select the alarm sensor operation between <NO>, <NC> and
<OFF>.
ALARM OUT SET : Set the alarm out port matched to the alarm input port.
AUTO SET : Sets the pattern and scan
action for the corresponding alarm
input. When the alarm is generated, the
camera moves to the preset position
coupled to the corresponding alarm.
Presets 1 ~ 8 are coupled with alarms
1 ~ 8 inputs respectively, and the preset
9 is coupled to the motion detection.
The camera stops and remains in the
corresponding preset position for the
defined <DWELL TImE>, and performs
pattern or scan action defined by the <AUTO SET>. Setting to <OFF> will
discard with the pattern or scan action after moving to the preset position.
- PATTERN 1 ~ 3 : Defined pattern action
- HALF1 : Patterns 1 and 2 in serial action
- HALF2 : Patterns 2 and 3 in serial action
- WHOLE : Patterns 1, 2 and 3 in serial action
- SCAN 1 ~ 4 : Predefined SCAN action
M
The <ALARM1> is used as external switching signal if the <DAY/NIGHT> is set to
<EXT>.
AUX OUT CONTROL : Sets whether to
sustain the alarm output despite of the
alarm generation or to output alarm out
signal while the coupled alarm is alive.
When selected <OFF>, outputs alarm
only if the alarm is generated. When
selected <ON>, it always outputs
alarm out signal despite of the alarm
generation.
AUTO SET
ALARM1
ALARM2
ALARM3
ALARM4
ALARM5
ALARM6
ALARM7
ALARM8
MOTION
AUX OUT CONTROL
OUT1
OUT2
OUT3
English _
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF

Publicidad