Descargar Imprimir esta página

GreenWorks Pro CRT426 Guía De Montaje página 29

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
Display
Description
The right blade mo-
tor fails.
The 6pin connector
between the right
blade motor and the
left blade controller
is loose.
The temperature of
the left blade motor
is too high.
The temperature of
the right blade mo-
Blade failure
tor is too high.
The 30pin connec-
tor between the ve-
hicle wiring har-
ness and the right
balde controller is
loose.
The 30pin connec-
tor between the ve-
hicle wiring har-
ness and the right
balde controller is
loose.
PMU is slightly
overcurrent or
overtemperature.
PMU shutdown
protection
PMU failure
The battery inser-
ted does not work
(not specified bat-
tery).
The inserted bat-
tery pack is defec-
tive.
English
Status code
MR22
ML23
MR23
ML25
MR25
PMU11
PMU 12
PMU 13
28
Cause
Solution
Motor failure
Contact the service
center for help.
Loose connector
Power off the ma-
chine, and power
Motor temperature
on again after the
is too high.
controller cools
down.
Contact the service
Loose connector
center for help.
Contact the service
Loose connector
center for help.
Please reduce the
The PMU system is
intensity of use to
over-temperature or
avoid abnormal
over-current
shutdown
PMU protection is
Restart the ma-
activated because
chine.
of the work stress.
Check the battery
The power of the
pack capacity in the
whole machine is
battery compart-
too low
ment
Battery compart-
Contact the service
ment fails
center for help.
Battery pack is not
Replace with the
applicable.
specified battery
pack.
Make sure the bat-
The battery pack is
tey pack is func-
defective
tional.