Descargar Imprimir esta página

Kärcher IVM 60/24-2 M ACD WS Manual De Instrucciones página 28

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 69
Note
The device must be switched off immedi-
ately in the event of a malfunction. The mal-
function must be eliminated before
switching the device on again.
If the malfunction cannot be corrected, the
device must be checked by the Customer
Service department.
Suction turbine does not start up
1. Check the socket and the power supply
fuse.
2. Check the mains cable and the mains
plug of the device.
3. Switch the device on.
Suction power decreases
1. Close the unsealed suction connection
(see chapter Closing the suction con-
nection).
2. Remove the blockages from the suction
nozzle, the suction pipe or the suction
hose.
3. Check that the suction head and the dirt
receptacle are correctly seated.
4. Empty the dirt receptacle (see chapter
Emptying the dirt receptacle).
5. Check the seating of the filter and cor-
rect if necessary.
6. Replace the main filter (see chapter Re-
placing the main filter).
7. Replace the micro-fleece (see chapter
Replacing the micro-fleece).
8. Check the condition of the inert liquid.
a Check the filling level of the inert liq-
uid, top up the inert liquid if necessary
(see chapter Fill the dirt receptacle
with inert liquid).
b Check the quality of the inert liquid, re-
place the inert liquid if necessary (see
chapter Drain the inert liquid from the
dirt receptacle and chapter Fill the dirt
receptacle with inert liquid).
Suction power not present
The mechanical switch-off interrupts the
volume flow because there is too little inert
liquid in the dirt receptacle.
1. Top up the inert liquid (see chapter Fill
the dirt receptacle with inert liquid).
Escaping dust when vacuuming
1. Check the seating of the dirt receptacle.
28
2. Check the seating of the filter and cor-
rect if necessary.
3. Replace the main filter (see chapter Re-
placing the main filter).
4. Top up with inert liquid when using the
device with a wet separator (see chapter
Fill the dirt receptacle with inert liquid).
At the end of its service life, the device is to
be disposed of in accordance with statutory
regulations.
The warranty conditions issued by our rele-
vant sales company apply in all countries.
We shall remedy possible malfunctions on
your appliance within the warranty period
free of cost, provided that a material or
manufacturing defect is the cause. In a war-
ranty case, please contact your dealer (with
the purchase receipt) or the next author-
ised customer service site.
(See overleaf for the address)
Technical data
Electrical connection
Mains voltage
Phase
Power frequency
Power
Protection type
Protection class
Maximum permissible
mains grid impedance
Dimensions and weights
Typical operating weight
Length x width x height
Filter area
Ambient conditions
Storage temperature
English
Disposal
Warranty
V
~
Hz
W
Ω
kg
mm
2
m
°C
220-
240
1
50-60
2100
IPX4
I*
0.195+
j0.122
108
1020 x
680 x
1490
2.24
-10-40