Descargar Imprimir esta página

SATA SATAjet 100 B F RP Instrucciones De Servicio página 450

Ocultar thumbs Ver también para SATAjet 100 B F RP:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 126
Operating Instructions SATAjet 100 B F RP/HVLP, B P
7.1. Adjustment of the Spray Gun Inlet Pressure
• Fully pull trigger and adjust spray gun inlet pressure (see chapter 2)
according to one of the follwing sections [3-1], [3-2], [3-3] to [3-4],
then release trigger.
• With [3-2], [3-3] and [3-4], the air micrometer [1-13] has to be fully
opened and in vertical position.
• If the required spray gun inlet pressure is not reached, the pressure
at the compressed air circuit has to be increased; too high pressure
results in too high trigger forces.
[3-1] SATA adam 2 (accessory / accurate method).
[3-2] Separate analogue gauge with regulation device (accessory).
[3-3] Separate analogue gauge without regulation device (acces-
sory).
[3-4] Pressure regulation at the compressed air circuit (least ac-
curate method):
rule of thumb: pressure at the pressure reducer must be set 0.6
bar higher than the recommended spray gun inlet pressure per
every 10 m of air hose (inner width 9 mm).
7.2. Adjustment of the Material Flow
und [4-4] - material flow control fully opened
With the material flow control fully opened, the wear of the fluid tip and
paint needle is reduced to a minimum. Please select the correct nozzle
size depending on the material to be applied and the required applica-
tion speed.
7.3. Adjustment of the Spray Fan Pattern
• Adjust flat fan (factory setting) [5-1].
• Adjust round fan [5-2].
7.4. Painting
Fully pull trigger for painting [6-1]. Operate spray gun according to [6-2].
Maintain spray distance as described in chapter 2.
Information!
Information!
[4-1], [4-2], [4-3]
US
443

Publicidad

loading

Este manual también es adecuado para:

Satajet 100 b f hvlpSatajet 100 b p