Operating Instructions SATAjet 100 B F RP/HVLP, B P
Malfunction
Spray gun leaks from
the fluid tip ("fluid tip
aperture")
11. Disposal
Recycle the completely empty spray gun. To protect the environment, bat-
teries and residual paint have to be disposed in an appropriate way and
separately from the spray gun. Please observe local legislation!
12. After Sale Service
Please ask your SATA dealer for accessories, spare parts and technical
support.
13. Warranty / Liability
The SATA General Conditions of Sale and Delivery and further contractual
agreements, if applicable, as well as the valid legislation at the time apply.
SATA cannot be held responsible especially in the following
cases:
• When the operating instructions are disregarded
• When the product is used in other than the intended ways of usage.
• When untrained staff is employed.
• When no personal protection equipment is worn
• When no original accessories and spare parts are used.
• When the product is manipulated, tampered with or technically modi-
fied.
• In case of normal wear and tear.
• In case when the product has been exposed to untypical shockloads
and impacts during usage.
• Assembly and disassembly
14. Spare Parts [12]
Art.
Description
No.
1826
Pack of 4 anti-drip devices for 0.6 l PVC gravity flow cup
Cause
Contamination be-
tween paint needle tip
and fluid tip
Damaged nozzle set
Corrective action
Clean fluid tip and
paint needle, observe
chapter 8
Replace nozzle set,
chapter 9