LED 2
Device Status or Error
Add Mode (lasts 120 seconds or
4-blinks
until a device is added)
Delete Mode (lasts 120 seconds or
2-blinks
until a device is deleted)
Successful add node/remove
Solid
node/replication (lasts 60 seconds)
Add node attempt failed because
Solid with
node already in network (lasts 60
one blink
seconds)
LED L3 (Yellow)
L3 flashes with every communication between the module and its radio unit in Idle mode, and with every com-
munication with Alarm.com in Connected mode. In PowerSave mode, this LED flashes in unison with LED 2.
LED L4 (Green)
L4 indicates the HSPA signal level as a number of flashes (0 to 5 bars). The number of bars may not corres-
pond to the bars shown on your cell phone. A level of 5 bars is obtained only in the strongest signal conditions.
Signal level is updated every ten seconds if it fluctuates, or every 30 seconds if it is fairly stable. If L4 is not
flashing it indicates one of the following states:
The module is in PowerSave mode
l
The module just powered up
l
There is no HSPA coverage in the area. Alarm.com recommends a steady signal level of 2 or higher for
l
proper operation of the module
Note: In Connected Mode, the LED toggles on and off.
LED L5 (Yellow)
L5 indicates Z-Wave errors. See the table below for more information.
LED 5
Device Status or Error
No other nodes are in the network
2-blinks
(lasts until a device is added to the
network)
Learn mode error (lasts 60
5-blinks
seconds)
No Home ID present (lasts until the
6-blinks
module connects to Alarm.com
and is configured)
Various Module States (Modes)
There are four module states, or modes, as described in the following:
In this mode you can add a device to the local Z-Wave network.
Devices cannot be added to a network if they are already a part
of a network.
In this mode you can delete a device from a Z-Wave network. A
device can only be in one network at a time, and must receive a
"delete" command before it can be learned into a new network.
After receiving this signal, leave all devices by the HSPA
module for 1 minute. Locks must be left next to the module for 4
minutes.
Device you attempted to add to a network is already in a
network, and must be "deleted" before it can join a new
network.
No devices have been added that can be controlled by the
HSPA module yet. See above for instructions on how to add
devices.
Learn mode error (lasts 60 seconds).
When the HSPA module first connects to Alarm.com it is
configured with a necessary unique network ID.
- 19 -
Description
Description