TECHNICAL DATA
TECHNICAL DATA
Fume discharge (mm)
Heatable room size (m3)
Hourly consumption (kg/h)
Minimum draw (Pa)
Fumes temperature (°C)
Fumes mass flow (g/s)
Power output in heating (kW)
Output (%)
CO emissions at 13% of O2
(mg/Nm3)
OGC emissions at 13% of O2
(mg/Nm3)
NOx emissions at 13% of O2
(mg/Nm3)
DUST emissions at 13% of O2
(mg/Nm3)
Energy efficiency class
Energy efficiency index
Fuel type, Length (mm)
Maximum fuel humidity (%)
Combustion chamber size (L x H x W
mm)
Distance from flammable walls Side; Back;
Front (cm)
Install the stove with at least 1 meter of Ø 150 pipe certified according to the EN1856-2 standard._x000D_
The pipes to be used for fume discharge must be pipes suitable for wood stoves: made of painted steel or stainless steel,
diameter 150 mm. The flue outside must be insulated.
COMBUSTION CHAMBER REFRACTORY INSTALLATION
COMBUSTION CHAMBER REFRACTORY INSTALLATION
83103600 - 1.0 - 14/12/2022
EVSL8
EVSL105S
150
150
140 - 200
180 - 270
2.4
2.9
10
10
233
234
6.7
6.7
8.0
10.5
86.0
88.0
644
273
25
12
87
76
24
10
A+
A+
114
115
Wood Logs
Wood logs
250 mm
330 mm
20
20
300 x 490 x 280
390 x 490 x 400
40; 20; 150
40; 40; 150
EVSL5
150
40 - 100
1,4
10
202
5,6
5,0
85,5
598
32
98
22
A+
113
Logs of Wood
200mm
20
240 x 370 x 240
40; 15; 150
For the EVSL5 and EVSL6 install the upper vermiculite
as follows:
1
Lift the refractory into the chamber and move past
the support screws.
2
Turn the refractory and rest it on the rear supports.
3
Once positioned, push it back until it touches the
rear wall.
EN
EN
EVSL6
150
70 - 160
1,8
11
223
5,7
6,0
85,3
545
29
93
18
A+
113
Logs of Wood
250mm
20
240 x 370 x 270
40; 20; 150
14
14