3. Installing the indoor unit
1
3
5
■ TPKFYP004/006/008/012LM140
H
A
0
7.2 (9/32)
11 (7/16)
23.5 (59/64)
44.7 (1-49/64)
69.7 (2-3/4)
76 (2-63/64)
82.2 (3-15/64)
119.7 (4-23/32)
144.7 (5-45/64)
177.2 (6-31/32)
244.7 (9-41/64)
C
257.2 (10-1/8)
■ TPKFYP015/018LM140
H
0
7.2 (9/32)
16 (5/8)
23.5 (59/64)
32.2 (1-17/64)
44.7 (1-49/64)
76 (2-63/64)
107.2 (4-7/32)
119.7 (4-23/32)
132.2 (5-13/64)
157.2 (6-3/16)
244.7 (9-41/64)
257.2 (10-1/8)
en
A
C
D
3
2
4
Fig. 3-1
G
D
E
F
210
(8-17/64)
100
(3-15/16)
K
Hole centre
side
J
I
H
Fig. 3-2
G
F
D
210
(8-17/64)
100
(3-15/16)
K
Hole centre
side
J
I
H
Fig. 3-3
A Sleeve
B Hole
C (Indoors)
B
D Wall
E (Outdoors)
E
Fig. 3-4
3.1. Check the indoor unit accessories (Fig. 3-1)
The indoor unit should be supplied with the following accessories.
PART NUMBER
1
2
3
4
5
3.2. Installing the wall mounting fixture
3.2.1. Setting the wall mounting fixture and piping positions
► Using the wall mounting fixture, determine the unit's installation position
and the locations of the piping holes to be drilled.
Warning:
Before drilling a hole in the wall, you must consult the building contractor.
mm (inch)
[Fig. 3-2, Fig. 3-3]
A Mount board 1
B Indoor unit
C Bottom left rear pipe hole (ø75 mm, 2-61/64 inch)
D Bottom right rear pipe hole (ø75 mm, 2-61/64 inch)
25 (63/64)
E Bottom right rear condit cable hole (ø75 mm, 2-61/64 inch)
0
F Knockout hole for left rear hole (P004/006/008/012: 105 × 215 mm,
16 (5/8)
3-15/16 × 9-27/32 inch, P015/018: 105 × 300 mm, 3-15/16 × 11-13/16 inch)
20 (25/32)
57.2 (2-1/4)
G Bolt hole (4-ø9 mm, 23/64 inch hole)
107.2 (4-7/32)
H Tapping hole (6-ø4.3 mm, 11/64 inch hole)
132.2 (5-13/64)
I Hole centre
157.2 (6-3/16)
189.7 (7-15/32)
J Align the scale with the line.
230 (9-1/16)
K Insert scale.
274 (10-25/32)
3.2.2. Drilling the piping hole (Fig. 3-4)
B
► Use a core drill to make a hole of 75 - 80 mm, 2-61/64 - 3-5/32 inch diameter
in the wall in the piping direction, at the position shown in the diagram to
the left.
► The hole should incline so that the outside opening is lower than the
inside opening.
► Insert a sleeve (with a 75 mm, 2-6/64 inch diameter and purchased locally)
through the hole.
Note:
The purpose of the hole's inclination is to promote drain flow.
mm (inch)
25 (63/64)
0
25 (63/64)
57.2 (2-1/4)
69.7 (2-3/4)
82.2 (3-15/64)
123.5 (4-55/64)
177.2 (6-31/32)
189.7 (7-15/32)
230 (9-1/16)
274 (10-25/32)
B
ACCESSORY
QUANTITY LOCATION OF SETTING
Mount board
1
Tapping screw 4 × 25
12
Felt tape
3
Band
3
Clamp
1
Fix at the back of the unit