ELECTRICAL CONNECTION
(only intended for qualiied personnel)
Disconnect the equipment from electrical mains power supply before carry-
ing out any operations on the hood.
Ensure that the wires inside the hood are not disconnected or cut:
in the event of damage, contact your nearest Servicing Department.
Refer to qualiied personnel for electrical connections.
Connection must be carried out in compliance with the provisions of law in force.
Before connecting the hood to the electrical mains power supply, check that:
П voltage supply corresponds with what is reported on the data plate located inside the
hood;
П the electrical system is compliant and can withstand the load (see the technical specii-
cations located inside the hood);
П the power supply plug and cable do not come into contact with temperatures exceed-
ing 70 °C;
П the power supply system is efectively and properly connected to earth in compliance
with regulations in force;
П the socket used to connect the hood is within reach.
In case of:
П devices itted with cables without a plug: the type of plug to use is a ''standardised'' one.
The wires must be connected as follows: yellow-green for earthing, blue for neutral and
brown for the phase. The plug must be connected to an adequate safety socket.
П ixed equipment not provided with a power supply cable and plug, or any other device
that ensures disconnection from the electrical mains, with an opening gap of the con-
tacts that enables total disconnection in overvoltage category III conditions.
Said disconnection devices must be provided in the mains power supply in compliance
with installation regulations.
The yellow/green earth cable must not be cut of by the switch.
The Manufacturer declines all responsibility for failure to comply with the safety regulations.
FUMES DISCHARGE
HOOD WITH INTERNAL RECIRCULATION (FILTERING)
In this model, the air passes through the zeolite-carbon ilters to be
puriied and recycled in the environment.
Ensure that the active carbon ilters are assembled into the hood, if not,
install them as indicated in the assembly instructions.
In this version the check valve must not be assembled: remove it if it is on the air
outlet itting of the motor.
ASSEMBLY INSTRUCTIONS
only intended for qualiied personnel
The hood can be installed in various conigurations.
The generic assembly steps apply to all installations; for each case, follow
the speciic steps provided for the required installation.
OPERATION
WHEN TO TURN ON THE HOOD?
Switch on the hood at least one minute before starting to cook to direct fumes and vapours
towards the suction surface.
After cooking, leave the hood operating until complete extraction of all vapours and odours.
By means of the Timer function, it is possible to set auto switch-of function which will allow
the hood to turn of automatically after 15 minutes of operation.
WHICH SPEED IS TO BE SELECTED?
1st speed: maintains the circulation of clean air with low electricity consumption.
2nd speed: normal conditions of use.
3rd speed: presence of strong odours and vapours.
4th speed: rapid disposal of odours and vapours.
WHEN SHOULD THE FILTERS BE WASHED OR REPLACED?
The metal ilters must be cleaned every 30 hours of operation.
The zeolite-carbon ilters must be reactivated every 18 months and replaced every 3 years.
For further details see the "MAINTENANCE" chap.
TOUCH PUSHBUTTON PANEL
ON/OFF (Blue led steady on)
Motor on/of and Speed 1
ON/OFF (blue led lashing)
If pressed for more than 3 seconds, it activates the 24h cycle (1h ON -> 3h
OFF -> 1h ON)
the function deactivates if:
- The motor turns of (key
- After 24h
Speed 2 activation
Speed 3 activation
Speed 4 is only active for a few minutes, then speed 3 activates.
Light on/of
TIMER
(red LED lashing)
Auto switch-of after 15 min.
The function deactivates (red LED of ) if:
- The motor turns of (key
- The speed is changed.
USING THE RADIO CONTROL
WARNINGS!:
Place the hood away from sources of electromagnetic
waves (e.g. microwave ovens), which could interfere
with the radio control and with the hood electronics. The maxi-
mum operating distance is 5 metres, that may vary according to
the presence of electromagnetic interferences.
Radio control operated at 433.92MHz.
The radio control consists of two parts:
- the receiver built into the hood;
- the transmitter shown here in the igure.
DESCRIPTION OF TRANSMITTING COMMANDS
UP
Motor switch-on and speed increase from 1 to 4. Speed 4 is only active for a
few minutes.
DOWN
Speed decrease and motor switch-of.
Light ON-OFF
TIMER ON: The motor automatically switches of after 15 min.
The function is automatically disabled if the motor is switched of (
Command transmission active
RADIO CONTROL CODE CHANGE
With only one radio control, go directly to point 2.
With several radio controls in the same room, a new code can be created by following the
procedure below.
Disconnect the power to the hood before starting the procedure.
1) - CREATE A NEW CODE
The procedure is to be carried out on the radio control.
• Press LIGHT
and TIMER
• Press DOWN
on the radio control: saving is conirmed by three brief lashes of the
display. The new code cancels and replaces the previous default code.
14
)
).
simultaneously until the display starts lashing.
key)