INSTALLATION AND FRAMING INSTRUCTIONS
The alcove opening dimensions should be at least 1/8" (3mm) larger than dimensions shown on
spec page for the model being installed.
For the best fit, the opening measurements should be verified against the actual
shower base received.
1a. Ensure that the floor and stud walls are square and plumb on a level floor as shown in Figure A.
Provide a 5" x 5" (127 x 127 mm) opening in the floor for the drain and refer to the product rough-in
on the specification page for actual drain location.
2
DRAIN ASSEMBLY
FIGURE B
The shower base requires purchasing a round shower strainer type drain for use with a standard 2" (51 mm)
plastic schedule 40 waste pipe. Figure B shows the typical drain assembly. Before installing drain into the
shower base, remove strainer. (Fig B) This will be installed after shower base is in its final position. Cut the
waste pipe height so that the drain body will fit snug in the shower base. Apply silicone sealant
between the drain body and shower base.
NOTE: Drain not included and must be purchased separately.
90°
2" (51 mm)
C/L
PVC Waste Pipe
(See Product Rough-In on specification page for Drain Location)
FIGURE A
DRAIN ASSEMBLY
Rubber
Caulking
Gasket
Drain
Body
Silicone
Sealant
Rubber
Gasket
90°
Opening 5" x 5"
(127 x127 mm)
Strainer
Shower
Base
Fiber
Gasket
Locking
Nut