If exhaustductworkmustrun throughan unheatedarea,the duct shouldbe insulatedandslope slightlydown
towardsthe exhausthood to reducecondensationand lint build-up.
If an existingexhaustsystemis to be usedwith your newdryer,you mustbe sure:
• The exhaustsystemmeetsall local,stateand nationalcodes.
• That plasticflexible duct is not used.
• Tocompletelyinspectand clean all lint accumulation from the interiorof the duct.
• The duct is not kinkedor crushed.
• Theexhausthooddamperopensandclosesfreely.
The static pressurein anyexhaustsystemmustnot exceed0.92 inchesof watercolumn,or be less than 0.
This can be measuredwith the dryer runningwith a manometerat the pointwherethe exhaustduct connects
to the dryer. A no heatsettingshouldbe used. The dryertumblershouldbe emptyand the lintfilter clean.
Inspectand cleanthe interioror the exhaustsystemat least oncea year. Disconnect e lectricalserviceprior
to cleaning. Checkthe gas line on gas dryersanytimethe dryer is moved.
Frequentlycheckto be sure the exhausthood damperopensand closesfreely.
NON EXHAUSTED
INSTALLATIONS
If the electric
dryer is not exhausted
to the outside,
the exhaust
must not terminate
directly
behind the dryer.
Use a rectangular
vent kit along with a dacron
mesh lint bag (see Accessories).
Maintain
a 6" (15.2 cm)
clearance
between
the back of the control
panel and the wall.
Although
the lint screen and lint bag will retain
most of the lint, a certain amount
will be expelled
into the laundry
area.
WARNING:
IF THE DRYER
IS NOT EXHAUSTEDTOTHE
OUTSIDE,
SOME FINE LINT WILL
BE
EXPELLED
INTO THE LAUNDRY
AREA.
AN ACCUMULATION
OF DUST OR LINT IN ANY AREA
OF THE
HOME CREATES
A FIRE HAZARD.
ANY LINT ACCUMULATIONS
MUST BE CLEANED
FREQUENTLY.
GAS REQUIREMENTS
Use only Natural or LP (liquid propane)
gases.
THE INSTALLATION
MUST CONFORM
WITH LOCAL CODES,
OR IN THE ABSENCE
OF LOCAL CODES,
WITH THE NATIONAL
FUEL GAS CODE ANSI/Z223.1,
LATEST
REVISION
(FOR THE UNITED
STATES),
OR WITH THE CAN/CGA-B149
INSTALLATION
CODES
(FOR CANADA).
Gas dryers are equipped
with a burner orifice for operation
on NATURAL
gas.
If the dryer
is to be operated
on LP (liquid
propane)
gas,
it must
be converted
for safe and proper
performance
and must
be
converted
by a qualified
service
technician.
Conversion
kits from NATURAL
to LP, or LP to NATURAL
are
available
through
your local Maytag
dealer (see Accessories).
If other conversions
are required,
check with
the local gas utility for specific
information
concerning
conversion
requirements.
A 1/2" (1.27 cm) gas supply line is recommended
and must be reduced
to connect
to the 3/8" (1.0 cm) gas line
on the dryer.
The National
Fuel Gas Code requires
that an accessible,
approved
manual
gas shut off valve be installed
within 6 feet of the dryer.
Additionally,
a 1/8" (.3 cm) N.P.T.
National
Pipe Thread)
plugged
tapping,
accessible
for test gauge
connection,
must be installed
immediately
upstream
of the gas supply connection
to the dryer.
The dryer must be disconnected
from the gas supply piping system during any pressure testing of the system.
DO NOT re-use old flexible
metal gas line.
Flexible gas line must be design
certified
by American
Gas
Association
(CGA in Canada).
NOTE:
Any pipe joint compound
used must be resistant
to the action of any
liquefied
petroleum
gas.
NOTE: As a courtesy, most local gas utilities will inspect a gas appliance installation.
GAS IGNITION
-
This dryer uses an automatic
ignition system to ignite the burner.
There
is no constant
burning
pilot.