(Figure 4)
Auxiliary Pipe Connections and Accessories
Depending on the practice auxiliary pipe connections (necessary seal, cooling, seal
washing, liquiding, drain, etc and/or) pressure gauge, temperature gauge
connections can be used for controlling operational conditions.
- Pressure or vacuum gauges should be installed sturdy in measurement points
which are over flanges or very close to flanges by means of estimated 8 mm pipes
which are bended in spiral form. Air taking valves should be used for devices to
operate safely and precisely.
- There are connection places in every pump for discharging pump and removing
leakages in seal bed. (Fig. 5) Those connections can be connected to discharge tank
by means of pipes if requested. There should be isolation valve in pipe which is used
for pump discharging and this valve and pipe should be suitable with maximum
operational pressure of pump.
-Seal cooling, liquiding and washing pipes should be connected to correct places
over pump body which are specified for them.
11