Above the coin mechanism door, there are two push buttons having the following functions:
1 Programming Button
2 Test Vend Button
Programming Button: once programming is accessed, Command 00 appears on the display. Direct
access is possible from this main menu to several data or other submenus. Enter the command on Direct
selection keypad and press key B (ENTER) to confirm the selection.
Key B is also used to confirm and memorise data inserted through the keyboard; in this case the text
message "OK" appears on the display for a few seconds. To exit the programming or to go from a submenu
to a main menu simply press key A (ESC).
Every time the door opens, the selections, if present, that are out of service or not in "home position" (having
executed a quarter turn) will appear on the display (see Command 76). The selections can be reset (by
rotating them) by pressing button "B". If the door is closed again without having reset all the selections, the
event is recorded as an error displayed in Command 99 with code number 91.
ATTENTION: Rotating the selection to reset it with the door open could cause the product to fall to
the ground.
N.B.: With SPIRALI SLAVE connection enabled (see command 49), after the MASTER machine display,
access is gained to the display of the same data relevant to the SLAVE machine by simply pressing the A
(ESC) button.
Test Vend Button: simply press this button to test the functionality of the vending machine. All the
selections can be tested during this phase. At the end of the test, simply press the same button a second
time to return to normal operation. As an alternative an indication (ex. 12, 14...) could appear to indicate that
an irregularity has taken place during the functioning and the spirals indicated are out of service. Carry out
the selection shown on the display to reset. If a working mistake happens during the test, the tag of the spiral
or module will stay on the display; otherwise the test will go on to the next out-of-work spiral. If during the test
or the reset there should happen some errors, it means that the anomaly is not occasional but could result
from the breakage of some parts and a technical intervention is required.