Command 09 Displays totals cashed not clearable:
Use this command to display the totals regarding the transactions carried out from the initialization of the
machine. The available data are the following:
Total sold, tot. in counter, tot. in tubes, tot. banknotes, tot. given back, tot. given out manually by the tubes,
tot. cashed overprice, tot. discounted sales, tot. sales with system cash less, tot. sold with exact amount, tot.
cashed without sales, number of sales carried out, total value of the free vends, total number of the free
vends.
Command 10 Displays totals clearable:
This command has the same functions as command 09, but it can be cleared through command 92.
Command 11 Setting the selection sequences :
The function of this command is to set the dispensing of the same type of product in order to obtain a
uniform and progressive emptying of the tray, irrespective of the customer's choice.
Initially the command asks the operator to enable (option 1) or disable (option 0) the function.
If the option is active (1) the system asks the operator to enter the first selection that forms the sequence,
then asks the operator to assign a product code and price. Confirm each time by pressing ENTER. Add the
remaining selections that are part of the same sequence . Press ESC to conclude and confirm the first
sequence. At this point, another sequence may be entered, or exit the command by pressing ESC a second
time.
9.1.2

SETTING THE TEMPERATURE PARAMETERS

Command 40 Select refrigeration unit type on SLAVE:
The command, which is only accessible when a slave machine is enabled (see Command 49), allows you to
set the model of the connected slave machine.
If FAST SLAVE = 0
If FASTER SLAVE = 1
If the value is set at = 0 (FAST SLAVE), the values of Command 41 (internal temperature setting) are the
following: predefined +8°C, and can vary between +6 ÷ +25°C. Commands 45, 46 and 48 are also disabled.
Whereas if the value is set at = 1 (FASTER SLAVE), the same parameters apply as those for commands 41
to 48 of this manual.
The command setting MUST BE consistent with the machine model otherwise the machine
will not function correctly.
Command 41 Sets cabinet temperature:
This command sets the lower internal cabinet temperature of the machine, i.e. the temperature below which
the compressor is turned off. The preset value is +3°C. This value can be varied between +2 ÷ +25°C.
N.B.: with the SPIRAL SLAVE connection enabled (see Command 49), after setting the MASTER machine,
the same parameters for the SLAVE machine can be set.
FAST SLAVE: The preset value is +8°C. This value can be varied between +6÷+25°C.
FASTER SLAVE: The preset value is +3°C. This value can be varied between +2 ÷ +25°C.
Command 43 End defrosting temperature setting:
Every time the compressor pauses, the temperature of the evaporator is controlled by the evaporator feeler.
This command allows the evaporator temperature to be set, above which, after dripping, the compressor can
restart operating; this is to ensure complete defrosting of the evaporator itself. The command is preset at 3°C
and can vary between 3°C and 12°C.
N.B.: with the SPIRAL SLAVE connection enabled (see Command 49), after setting the MASTER machine,
the same parameters for the SLAVE machine can be set.