Descargar Imprimir esta página

Metabo HPT D 36DYA Instrucciones De Seguridad Y Manual De Instrucciones página 12

Taladro angular inalambrico

Publicidad

Idiomas disponibles

Idiomas disponibles

English
Table 2: Indications of the charge indicator lamp
ON/OFF at 0.5 sec. intervals
(RED)
Lights for 0.5 sec. at intervals
of 1 sec. (BLUE)
Lights for 1 sec. at intervals of
0.5 sec. (BLUE)
Lights continuously (BLUE)
Lights continuously
(Continuous buzzer sound:
about 6 sec.) (GREEN)
ON/OFF at 0.3 sec. intervals
(RED)
ON/OFF at 0.1 sec. intervals
(Intermittent buzzer sound;
about 2 sec.) (PURPLE)
NOTE
*1 If the red lamp continues to blink even after the
charger has been attached, check to confi rm that the
battery has been fully inserted.
*2 Battery overheated. Unable to charge.
Although charging will start once the battery has
cooled down even when left in situ, the best practice
is to remove the battery and allow it to cool down in a
shaded, well-ventilated location before charging.
*3 Malfunction in the battery or the charger
– Fully insert the battery.
– Check to confi rm that no foreign matter is stuck
to the battery mount or terminals. If there are no
foreign objects, it is probable that the battery
or charger is malfunctioning. Take it to your
authorized Service Center.
○ When the battery charger has been continuosly used,
the battery charger will be heated, thus constituting
the cause of the failures. Once the charging has been
completed, give 5 minutes rest until the next charging.
12
Before charging *
1
Charged at less than
50%
Charged at less than
80%
Charged at more than
80%
Charging complete
Overheat standby *
2
Charging impossible
*
3
(2) Regarding the temperature of the rechargeable
battery.
Rechargeable
Temperatures at which the battery
batteries
BSL36B18
(3) Regarding recharging time (At 68°F (20°C))
Table 4: Charging time
Charger
Battery
BSL36B18
NOTE
○ The recharging time may vary according to the
ambient temperature.
○ If charging takes a long time
– Charging will take longer at extremely low ambient
temperatures. Charge the battery in a warm
location (such as indoors).
– Do not block the air vent. Otherwise the interior will
overheat, reducing the charger's performance.
– If the cooling fan is not operating, contact a
metabo HPT Authorized Service Center for
repairs.
4. Disconnect battery charger from the receptacle.
CAUTION
Do not pull the plug out of the receptacle by
pulling on the cord.
Make sure to grasp the plug when removing from
receptacle to avoid damaging cord.
5. Remove the battery from the battery charger.
Supporting the battery charger with hand, pull out the
battery from the battery charger.
NOTE
Be sure to pull out the battery from the battery charger
after use, and then keep it.
Regarding electric discharge in case of new
batteries, etc.
As the internal chemical substance of new batteries
and batteries that have not been used for an extended
period is not activated, the electric discharge might
be low when using them the fi rst and second time.
This is a temporary phenomenon, and normal time
required for recharging will be restored by recharging
the batteries 2–3 times.
Table 3
can be recharged
32°F–122°F
(0°C–50°C)
UC18YSL3
Approx. 52 min

Publicidad

loading