Descargar Imprimir esta página

Orion 23803 Guía De Servicio Técnico Y Recambio página 13

Publicidad

Idiomas disponibles

Idiomas disponibles

TECHNICAL SPECIFICATIONS
Thread port
Wetted parts materials
Meter type
Flowrate
Maximum pressure
Temperature range
Accuracy (oil)
Accuracy (coolant solutions)
Viscosity range
Display
Units
Batteries
Weight (with nozzle and batteries)
Dimensions (without nozzle tube)
SPARE PARTS
Pos. Code
Description
1
2050800
Electronic module
2
2090301
Oval gears kit
3
2090307
Valve sealing kit
Flexible 90º outlet with
4
2285472
quarter turn opening
non-drip tip
Rigid outlet with quarter
5
2285470
turn opening non-drip tip
TROUBLESHOOTING GUIDE
Problem
Screen does not turn on.
Fluid not being dispensed.
The gun is not supplying fluid and
a work order has been validated.
Accuracy error.
Low flowrate.
Dispensed quantity excedes
preset value.
Alentec & Orion AB Grustagsvägen 4, SE-13840, Älta, SWEDEN · info@alentec.se · www.alentec.com
½" BSP / ½" NPT
Acetal, stainless steel, NBR, aluminum, brass, zinc plated steel
Oval gear
1-30 l/min (0.25 - 7.5 US gal/min)
1 - 100 bar (14 - 1450 psi)
-10 a 50 ºC (14 a 122 ºF)
±0,5 %
±1 %
Up to 2000 mPa.s
Graphic
Litres, galons, quarts, pints
4 x AA 1.5V
2.1 kg (4.6 lb)
297 x 89 x 155 mm (11.7" x 3.5" x 6.1") (length x width x height)
5
4
Posible cause
Discharged batteries.
Stand-by mode.
Loose batteries cover.
A work order is not validated.
You have activated the command with
the trigger held down.
Very high or low flowrates used.
Very high or low (water based fluid)
fluid viscosity.
Strainer damaged or dirty.
Low pump pressure
Very high flowrate.
2
Solution
Replace batteries.
Press UP/DOWN button.
Tighten battery cover screws.
See "Operation" section.
Release the trigger, cancel dispensing
and re-enter the order.
Calibrate.
Calibrate.
Replace or clean strainer.
Increase pump air pressure.
Adjust valve anticipation closing factor.
R. 05/23 105 277
EN
1
3
13

Publicidad

loading