Water Supply
The water supply should be ready at the point of installation.
The water supply pressure
should be a minimum
of 15 psig with a static pressure
not more than 80 psig.
(A wall
outlet directly behind the ice maker will make installation
easier.)
IMPORTANT:
1.
All installations
must be in accordance
with local plumbing
code requirements.
Professional
installation
is recommended.
2.
Make
certain
that the hoses are not pinched
or kinked
or damaged
during
installation.
3.
Check for
leaks after connection.
Tools required:
1/2in. open-end
wrench, Phillips screwdriver
Connecting
the water line:
1. Turn offmain
water supply. Turn on nearest faucet long enough to clear line of water.
2. Find a ½ in. to 3/4 in. vertical cold water pipe near the installation
location. The
distance should be less than 9 feet. The water supply hose provided with the ice
maker is about 9 feet long.
3. A shut-offvalve
must be installed to the main water supply.
If the water pipe has a
plain piece of copper tubing, attach a ¼" O.D. compression
union to the tubing and
remove the nut.
4.
Connect nuts of the water supply hose to tap and water inlet valve. Tighten
firmly by
hand, then one-half turn with wrench.
5. Turn on main water supply and tap. Check for water supply connection
leaks. Tighten
every connection
(including connections
at the water inlet).
Fig. A
This type of ice maker
does not require
a drain line.
The ice storage bin collects water
through ice cube melting.
The water level of the ice storage bin can be seen through
the
water level indicator tube. When required, the melt water must be discharged
through the
melt water drainage
nut on the front of the ice storage bin.
The nut must be tightened
afterwards.
(Do not loosen or screw offthis nut at other times.)
See Fig. A below.
probe
k
Water level
Water level indicator
tube
Melt water
drainage nut
Compressor
Drainage
Fig. B
tray
Lower drainage nut
12