Service Manual- SC370
Removal and Installation
Brush Motor (M1)
Removal
1.
Push the machine to a level floor.
2.
Ensure that the machine is off.
3.
Ensure the recovery tank is empty.
4.
Remove the recovery tank assembly.
5.
Disconnect the battery connector (A) and move the batteries.
6.
Remove the cable cover plate (B) and cut the wiring retaining clamp (C).
7.
Cut the heat-shrink tubing (D) then disconnect the electrical connections (E) of the brush motor.
8.
Remove 2 bolts (F) with the wrench (G), and then remove bolt (H).
9.
Loosen the clamp (I) and take out the brush deck.
A
E
H
B
D
C
F
G
41
34 Scrub System
I