Descargar Imprimir esta página

Gossen MetraWatt PROFITEST MF Serie Instrucciones De Servicio página 7

Ocultar thumbs Ver también para PROFITEST MF Serie:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 11
5
Technical Data (excerpt)
The complete technical data and characteristic values (display
ranges, resolution, uncertainties etc.) can be found in the com-
plete operating instructions.
Ambient Conditions
Accuracy
–5 ... + 50 C
Operation
–20 ... + 60 C (without rechargeable
Storage
batteries)
Relative humidity
Max. 75%, no condensation allowed
Elevation
Max. 2000 m
Nominal Ranges of Use
Voltage U
N
Frequency f
N
Overall voltage range
Overall frequency range
Waveform
Temperature range
Supply voltage
Line impedance angle
Probe resistance
Overload Capacity
R
1200 V continuous
ISO
U
, U
600 V continuous
L-PE
L-N
RCD R
R
440 V continuous
E
F
Z
, Z
550 V (Limits the number of measurements
L-PE
L-N
and pause duration. If overload occurs, the
instrument is switched off by means of a
thermostatic switch.)
R
Electronic protection prevents switching on
LO
if interference voltage is present
Protection with
Fine-Wire Fuse
FF 3.15 A 10 s,
Fuses blow at > 5 A
Electrical Safety
Protection class
II per EN 61010-1
Nominal Voltage
230/400 V (300/500 V)
Test voltage
3.7 kV, 50 Hz
Measuring category
CAT III 600 V and CAT IV 300 V
Pollution degree
2
Fuses
L and N terminals
1 fuse link ea.
FF 3.15 A/500G 6.3 x 32 mm
Mechanical Design
Dimensions
W × L × D = 260 × 330 × 90 mm
Weight
approx. 2.7 kg with rechargeable batteries
Type of protection
Housing: IP40; test probes: IP40
per EN 60529
Data Interfaces
Type
USB type B for PC connection
Typ
USB type A for connecting a USB keyboard, bar-
code reader or RFID scanner
Gossen Metrawatt GmbH
0 ... + 40 C
120 V
(108 ... 132 V)
230 V
(196 ... 253 V)
400 V
(340 ... 440 V)
16 ⅔ Hz
(15.4 ... 18 Hz)
50 Hz
(49.5 ... 50.5 Hz)
60 Hz
(59.4 ... 60.6 Hz)
200 Hz
(190 ... 210 Hz)
400 Hz
(380 ... 420 Hz)
65 ... 550 V
15.4...420Hz
Sinusoidal
0 C ... + 40 C
8 ... 12 V
Corresponds to cos  = 1 ... 0,95
< 50 k
6
Scope of Functions
PROFITEST MF ...
Testing of residual current devices (RCDs)
U
measurement without tripping the RCCB
B
Tripping time measurement
Measurement of tripping current I
Selective, SRCDs, PRCDs, type G/R
AC/DC sensitive RCDs, types B and B+
DC sensitive RDC-DDs and RCMBs
Testing of insulation monitoring devices (IMDs)
Testing Residual Current Monitoring Devices (RCMs)
Testing for N-PE reversal
Measurements of loop impedance Z
Fuse table for systems without RCDs
Without tripping the RCD, fuse table
1)
15 mA measurement
Earth resistance R
(mains operation)
E
I/U measuring method (2/3-wire measuring method via
measuring adapter: 2-wire/2-wire + probe)
Earthing resistance R
(battery operation)
E
3 or 4-wire measuring method via PRO-RE adapter
Soil resistivity E (battery operation)
(4-wire measuring method via PRO-RE adapter)
Selective earthing resistance R
E
with 2-pole adapter, probe, earth electrode and current
clamp sensor (3-wire measuring method)
Selective earthing resistance R
E
with probe, earth electrode and current clamp sensor
(4-wire measuring method via PRO-RE adapter and current
clamp sensor)
Earth loop resistance R
(battery operation)
ESCHL
with 2 clamps (clip-on current transformer direct and clip-
on current transformer via PRO-RE/2 adapter)
Measurement of equipotential bonding R
automatic polarity reversal
Insulation resistance R
ISO
Variable or rising test voltage (ramp)
Voltage U
/ U
/ U
/ f
L-N
L-PE
N-PE
Special measurements
Current measurement with clamp I
Power measurement with clamp S
Rotating Field Direction
Earth leakage resistance R
E(ISO)
Voltage drop (U)
Standing-surface insulation Z
ST
Meter start-up (kWh test)
Leakage current with PRO-AB adapter (IL)
Residual voltage test (Ures)
Intelligent ramp (ta + I)
Electric vehicles at charging stations (IEC 61851-1)
Documentation of fault simulations at PRCDs with the
PROFITEST PRCD adapter
Features
Selectable user interface language
Memory (database for up to 50,000 objects)
Automatic test sequences function
USB port type A (connection of USB keyboard/barcode
reader/RFID scanner)
USB port type B (data transmission)
PC database and report generating software IZYTRONIQ
Measuring category: CAT III 600V / CAT IV 300 V
DAkkS calibration certificate
1)
The so-called live measurement is only advisable if there is no bias cur-
rent within the system. Only suitable for motor protection switches with
small nominal current values.
15 mA test current, only applies if RCD is set with IΔN = 30 mA; other-
wise test current = ½ · IΔN of the pre-set RCDs
2)
as of firmware 1.0.3
3)
currently available languages D, GB, I, F, E, P, NL, S, N, FIN, CZ, PL
4)
IZYTRONIQ BUSINESS Starter (IZYTRONIQ CLOUD)
exception PROFITEST MF XTRA (LEMONGREEN): IZYTRONIQ BUSI-
NESS PROFESSIONAL (IZYTRONIQ CLOUD)
F
/ Z
L-PE
L-N
(mains operation)
(battery operation)
LO
, I
L
AMP
2)
S
3)
4)
?
7

Publicidad

loading