Unplug machine from electrical outlet before doing
any maintenance.
Changing The Brush Strip
To replace brush strip, push button (32), remove the
side plate (26) and rotate the brush so that the brush
strip (27) can be pulled out of the opening. Ensure
that the new brush strip is fully inserted, then press
the side plate back into place.
NOTE: Ensure plate is locked in place.
Changing The Paper Bag
If red light (3) shows, change paper filter bag.
Pull cover release latch (5) forward and lift the cover
from the dust bag housing. Slide the dust bag sealing
plate (28) from the holder (29). slide the sealing plate
(28) of a new bag into the holder and push firmly in.
Insert cover into dust bag housing. Push it forward
then lock it in place by pushing down the cover
release latch.
Changing The Motor Filter
Motor filter (30) should to be replaced after 20 filter
bags have been used. Lift the front of the filter slightly
and slide it out of the slot. Install new filter and press
firmly ensuring filter is completely in place.
NOTE: Hospital grade filters are available.