Code
Type
75
[W]
Coolant pressure too low.
76
[W]
Cooling unit not connected
Wire feeder
80
[W]
door open.
Error during USB
85
[W]
firmware updating.
Arc does not strike within the timeout (inching
98
[W]
timeout).
99
[E]
Machine is powering down.
66
Error Description
Action
Check the coolant level. Check the centrifugal
pump turns correctly. If it does not turn
correctly, release using a release screw.
If the problem persists, contact technical
assistance.
Check the pressure switch connection is intact.
If the problem persists, contact technical
assistance.
Check that the door of the wire feeder
compartment door is properly closed. If the
problem persists, contact technical assistance.
Make sure the USB key is correctly inserted.
If the problem persists, contact technical
assistance.
Check that the "Max Inching" function is
correctly set. If the problem persists, contact
technical assistance.
Wait for the power source to power down.
During this stage, do not turn the power
source back on by turning the mains switch
because the power source would lock. Turn off
the machine, wait for at least 30 seconds and
turn back on.