Special Functions; Deleting The Memory - Nice HOPP HO7124 Instrucciones Y Advertencias Para La Instalación Y El Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 51
L8
List of
L1
faults
L2
L3
L4
L5
L6
L7
L8
Note – The factory settings are highlighted in grey.
01. Press and hold down the "Set" key for approx. 3 seconds.;
02. Release the key when LED "L1" starts flashing;
03. Press the "" or "u" key to move the flashing LED to the LED representing the "input LED" of the parameter to be modified;
04. Press and hold the "Set" key through to completion of point 06;
05. Wait approx. 3 seconds, until the LED representing the current level of the parameter to be modified illuminates;
06. Press keys "" or "u" to move the LED representing the value of the parameter;
07. Release the "Set" key;
08. Wait 10 seconds (maximum time) to exit the programming mode.
Note – During this procedure, points 03 to 07 need to be repeated when programming other parameters during the phase itself .

6.3 - Special functions

6.3.1 - Function: "Move anyway"
This function allows the automation to be operated even when any of the safe-
ty devices does not work correctly or is out of use.
The automation can be controlled in the "hold-to-run", mode. Proceed as fol-
lows:
01. Send a command to operate the gate using a transmitter or a key selector,
etc. If everything operates correctly, the gate will move normally, otherwise
proceed as follows;
02. within 3 seconds, activate the control again and keep it activated;
03. after approximately 2 seconds, the gate will perform the required move-
ment in "hold-to-run"; mode; i.e. the gate will continue to move only as
long as the control is activated.
If the safety devices do not operate, the flashing light flashes a few times to indi-
cate the kind of problem (see chapter 6 - Table 10).
Number of manoeuvres
Below 80% of the limit
Between 81% and 100% of the limit
Beyond 100% of the limit
8 – English
www.metalines.com
Manoeuvre 1 result (most recent)
Manoeuvre 2 result
Manoeuvre 3 result
Manoeuvre 4 result
Manoeuvre 5 result
Manoeuvre 6 result
Manoeuvre 7 result
Manoeuvre 8 result
TABLE 8 - Programming procedure second level functions
TABLE 9 - "Maintenance light"
Signal
Light on for 2 seconds at the start of the opening manoeuvre.
Light flashing for the entire duration of the manoeuvre.
Light flashing continuously.
6.3.2 - Function: "Maintenance warning"
This function serves to indicate when automation maintenance is required. The
maintenance warning signal is emitted by a lamp connected to the "flash" or
"els" output when this output is programmed as a "maintenance indicator light"
The various light signals are shown in Table 9.
To program the limit value of the maintenance operations, see Table 7.

6.4 - Deleting the memory

To delete the control unit memory and restore all factory settings, proceed as
follows:
press and hold keys "" and "u" until leds L1 and L2 start flashing.
The type of fault that has occurred in
the last 8 manoeuvres can be establi-
shed
See TABLE 12 – Fault log.
SET
3 s
L1
SET
or
SET
or
SET
10 s
sales@metalines.com

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hopp ho7224

Tabla de contenido