Check Valve Replacement
1. Release all air pressure from air tank and unplug outfit.
2. Remove shroud.
3. Loosen the top and bottom nuts and remove the outlet tube.
4. Remove the pressure release tube and fitting.
5. Unscrew the check valve using a socket wrench.
6. Check that the valve disc moves freely inside the check valve and that the
spring holds the disc in the upper, closed position. The check valve may be
cleaned with a strong solvent.
7. Apply sealant to the check valve threads. Reinstall the check valve.
8. Replace the pressure release tube and fitting.
9. Replace the outlet tube and tighten top and bottom nuts.
10.Replace the shroud.
Motor
The motor has an automatic reset thermal overload protector. If the motor
overheats for any reason, the overload protector will shut off the motor. The motor
must be allowed to cool down before restarting. The compressor will automatically
restart after the motor cools.
If the overload protector shuts the motor off frequently, check for a possible voltage
problem. Low voltage can also be suspected when:
1. The motor does not get up to full power or speed.
2. Fuses blow out when starting the motor; lights dim and remain dim when motor
is started and/or is running.
Motor - Wiring Diagram
The motor connection diagram is located on the side of motor.