Descargar Imprimir esta página

Porter Cable CPFC2TV3520W Manual De Instrucciones página 17

Compresor de aire sin aceite

Publicidad

Idiomas disponibles

Idiomas disponibles

PROBLEM
Air leak from safety
valve.
Knocking Noise.
Compressor is not
supplying enough air
to operate
accessories.
Regulator knob has
continuous air leak.
Regulator will not
shut off air outlet.
Gauge is not
registering air
pressure reading.
CAUSE
Possible defect in safety valve.
Defective check valve.
Prolonged excessive use of air.
Compressor is not large
enough for air requirement.
Restricted air intake filter.
Hole in hose.
Check valve restricted.
Air leaks.
Pressure release valve on
pressure switch has not
unloaded head pressure.
Damaged regulator.
Malfunctioning or damaged
gauge
CORRECTION
Operate safety valve manually by
pulling on ring. If valve still leaks, it
should be replaced.
Remove and clean, or replace.
Decrease amount of air usage.
Check the accessory air
requirement. If it is higher than the
SCFM or pressure supplied by your
air compressor, you need a larger
compressor.
Clean or replace air intake filter. Do
not operate the air compressor with
the filter removed. See page 11.
Check and replace if required.
Remove and clean, or replace.
Tighten fittings. (See Air Leaks
Section of Troubleshooting Guide.)
Contact an Authorized Warranty
Service Center for replacement.
Contact an Authorized Warranty
Service Center for replacement.
17-ENG

Publicidad

loading