Fault
Condensation forms on the dispenser
unit.
Ice cubes have an unpleasant
odor/flavor.
Ice maker is not producing any ice.
Ice is not dispensed.
The dispenser light does not function.
28
Possible cause
The ice maker is switched off
(see "Switching off the ice maker").
The condensation heater does not
function.
Ice which is stored for a long time may
absorb odors which impair their taste.
The ice cube container is dirty.
Unsealed packages in the freezer
transfer odor/flavor particles
to the ice cubes.
Clean the inside of the appliance.
The ice cube container is in the false
position.
The water pressure is too low.
The freezer compartment temperature
is too high.
A wrong water valve has been installed.
The agitation function in the ice cube
container is switched off. The filling
level sensor is blocked.
Two ice cubes can by chance
be attached to each other.
These ice cubes, when joined together,
can block the ice chute so that
no further ice can be dispensed.
The bulb is defective.
Remedial action
You have to activate the condensation
heater.
–
Switch on the ice maker.
–
Simultaneously hold down
the LOCK OUT and the AGITATION
buttons for 3 seconds. The WATER
light and the ICE CUBE light flash
twice.
The ice maker is switched off and the
condensation heater works.
To re-activate the condensation heater:
–
Simultaneously hold down the
LOCK OUT and the AGITATION
buttons for 3 seconds. The WATER
light and the ICE CUBE light flash
once.
Dispose of old ice cubes. Use the ice
maker more frequently.
Empty and wash out the ice cube
container.
Check whether the frozen food has
been packed in airtight containers.
See section on "Odors".
Reinsert the container and slide
it backwards to the end position
(see section "Variable interior design").
Check water pressure. The water
pressure must be between 25 and
120 p.s.i. (1.72–8.25 bar).
Check temperature of the freezer
compartment. If required, lower
the temperature.
Self-tapping valves and
(4.76 mm) saddle valves reduce the
water pressure and may eventually
block the pipe.
Pull-out and empty the ice cube
container. Remove the ice on the
sensor.
Open the door. Remove all of the ice
out of the ice chute.
Change the bulb
(see "Changing the bulb").
3
inch
/
16