Fault
The ice maker is not producing enough
ice or the ice cubes are misshapen.
Ice is forming in the supply hose to the
ice maker.
Water is flowing out of the appliance.
 Close shut-off valve immediately.
Possible cause
The water pressure is too low.
The freezer compartment temperature
is too low.
Change the water filter.
The water pressure is too low.
The freezer compartment temperature
is too low.
The water pipe in the appliance
is defective.
The water pressure is too low.
A wrong water valve has been installed.
Remedial action
Check water pressure. The water
pressure must be between 25 and
120 p.s.i. (1.72–8.25 bar).
Check temperature of the freezer
compartment. If required increase
the temperature.
Instructions for changing the water
filter can be found in the section
"Water filter".
Check water pressure. The water
pressure must be between 25 and
120 p.s.i. (1.72–8.25 bar).
Check temperature of the freezer
compartment. If required increase
the temperature.
Call customer service immediately.
The valve may leak if the water
pressure is too low. The water pressure
must be between 25 and 120 p.s.i.
(1.72–8.25 bar).
Self-tapping valves and
(4.76 mm) saddle valves reduce the
water pressure and may eventually
block the pipe.
3