Descargar Imprimir esta página

BFT ZARA BT A80 Instrucciones De Instalación página 31

Ocultar thumbs Ver también para ZARA BT A80:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 48
TABLE "C" - ADV
DIP
Logic
Low Consumption
1
Disablement
Enables operation
2
of the I/O expansion
board
3
U-LINK activation
4
U-LINK version
INSTALLATION MANUAL
Cross out
Default
Description
setting used
With the gate shut, the power supply of the accessories is disabled, allowing the
stand-by consumption to be decreased.
OFF
OFF
exit the Low-Energy state by pressing buttons S1+S2 simultaneously.
The power supply of the accessories always remains active even with the gate closed;
ON
with this configuration, the stand-by power draw is greater.
OFF
The inputs of the expansion board are disabled.
OFF
The inputs of the expansion board are enabled; it is necessary to place a jumper on the
ON
SAFE inputs which are not used.
U-LINK is disabled, the logic settings and parameters of the board are made via the DIP
OFF
switch and TRIMMER interface.
U-LINK active, the logic settings and parameters of the board are made via the U-LINK
OFF
serial. The Trimmer and DIP switch interface is disabled, the position of the Trimmer
ON
and DIP switches does not affect the operation of the board.
Operation with virtual programming is signalled by alternating flashing of the ADV
and POWER LEDs.
OFF
U-LINK 2: if U-LINK is active dip 3=ON
OFF
ON
U-LINK 1: if U-LINK is active dip 3=ON
In the Low-Energy state, all LED notifications are suspended; it is possible to
- 31
ZARA BT A80

Publicidad

loading