1) GENERAL INFORMATION
The ZARA BT A80 control panel comes with standard factory settings. Any change
must be set by means of the TRIMMER and DIP SWITCH settings.
The Control unit completely supports the EELINK protocol.
Its main features are:
-
Control of 1 or 2 24V BT motors
Note: 2 motors of the same type must be used.
-
Electronic torque control with obstacle detection
-
Separate inputs for safety devices
-
Built-in radio receiver rolling code with transmitter cloning.
The board has a terminal strip of the removable kind to make maintenance
or replacement easier. It comes with a series of prewired jumpers to make the
installer's job on site easier.
The jumpers concern terminals: 70-71, 70-72, 70-74. If the above-mentioned
terminals are being used, remove the relevant jumpers.
TESTING
The ZARA BT A80 panel controls (checks) the start relays and safety devices
(photocells) before performing each opening and closing cycle.
If there is a malfunction, make sure that the connected devices are working
properly and check the wiring.
2) TUBE ARRANGEMENT Fig. A
Install the electrical system referring to the standards in force for electrical systems
CEI 64-8, IEC 364, harmonization document HD 384 and other national standards.
3) TERMINAL BOARD WIRING Fig. B
WARNINGS - When performing wiring and installation, refer to the standards in
force and, whatever the case, apply good practice principles.
Wires carrying different voltages must be kept physically separate from each other,
or they must be suitably insulated with at least 1mm of additional insulation.
Wires must be secured with additional fastening near the terminals, using devices
such as cable clamps.
All connecting cables must be kept far enough away from the dissipater.
WARNING! For connection to the mains power supply, use a multicore cable
with a cross-sectional area of at least 2x1.5mm
the regulations in force.
To connect the motors, use a cable with a cross-sectional area of at least
2.5mm
of the kind provided for by the regulations in force. The cable must
2
be type H05RN-F at least.
Terminal
10
11
14
15
20
21
26
27
41
42
43
44
45
42
43
40
42
43
40
41
42
43
50
51
52
INSTALLATION MANUAL
of the kind provided for by
2
Definition
MOT 1 +
Connection motor 1.
MOT 1 -
MOT 2 +
Connection motor 2.
MOT 2 -
AUX 1
Flashing light 24V output LED. Contact stays closed while leaf is operating.
24V
AUX 2
AUX 2 Configurable output - Default SCA
FREE CONTACT (N.O.)
2nd radio channel/SCA open gate warning light/Courtesy light/Area Light
(24V
/≤ 1A)
Refer to table "D" I/O Configuration DIP switch 6 and DIP switch 7
+ REF SWE
Limit switch common
SWC 1
Motor 1 closing limit switch SWC1 (N.C.).
SWO 1
Motor 1 opening limit switch SWO1 (N.C.).
SWC 2
Motor 2 opening limit switch SWC2 (N.C.).
SWO 2
Motor 2 opening limit switch SWO2 (N.C.).
Limit switch control motor 1.
SW 1
For actuators with single-wire limit switch control.
Limit switch control motor 2.
SW 2
For actuators with single-wire limit switch control.
- REF SWE
Limit switch common
SW 1
Limit switch control motor 1.
SW 2
Limit switch control motor 2.
- REF SWE
Encoder power supply, white cable
+ REF SWE
Encoder power supply, brown cable
ENC M1
Engine 1 encoder signal, green cable
ENC M2
Engine 2 encoder signal, green cable
24V-
Accessories power supply output.
24V+
Tested safety device power supply output (photocell transmitter and safety edge transmitter).
24 Vsafe+
Output active only during operating cycle.
4) TECHNICAL SPECIFICATIONS
Power supply
Power
Operating temperature range
Thermal overload protection
IP
Accessories power
supply
Auxiliaries maximum
LOCK
power draw
(only with I/O
expansion board)
AUX1
AUX 2 FREE CONTACT (N.O.)
Max.n° of transmitters that can be memorized
Usable transmitter versions:
All ROLLING CODE transmitters compatible with
Description
220-230V 50/60 Hz
200W
-20 / +60°C
Software
55
24V
(≤ 0.25 A)
12V
(≤ 1A)
24V
(≤ 0.6A)
24V
(≤ 0.3A)
24V
(≤ 1A)
128
2048 (only with expansion kit)
- 27
ZARA BT A80