96
ERROR NOTIFICATIONS
Code
Potential cause
01
The oven's NTC temperature
sensor is faulty.
02
Cooker surface NTC
temperature sensor short
circuit.
03
The NTC temperature of the
cooker surface is too high
04
The cooling NTC temperature
sensor is faulty.
05
Short circuit of the heater NTC
temperature sensor.
06
The heat dissipation NTC
temperature sensor is too hot.
07
The input voltage is too low.
08
The input voltage is too high.
09
Connection error.
Solution
Have the NTC temperature
sensor replaced.
Have the NTC temperature
sensor replaced.
Turn off the device and wait
for it to cool down, then
resume operation.
Have the NTC temperature
sensor replaced.
Have the NTC temperature
sensor replaced.
Turn off the device and wait
for it to cool down, then
resume operation.
Check if the input voltage is
lower than 150 V.
Check if the input voltage is
higher than 270 V.
Have checked whether the
connection error between
the display panel and the
induction cooker circuit
board is faulty and have the
communication cable replaced.