Descargar Imprimir esta página

Emos P5686 Manual Del Usuario página 3

Termostato de inmersión

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
GB | Immersion Thermostat
Properties
Immersion thermostat with display
Temperature range 5 °C – 80 °C (0.1 °C resolution)
Simple electrical connection via screwless terminals
Specifications
Switched load: max. 230 V AC; 5 A for resistive load; 1.5 A for inductive load
Power supply: 230 V AC
Temperature control range: 5 °C – 80 °C
Temperature measurement: 5 °C to 80 °C with 0.1 °C resolution accuracy ±1 °C
Temperature setting: 5 °C to 80 °C in 0.1 °C increments
Temperature differential setting: 0.1 °C to 15 °C with 0.1 °C resolution
Thermowell dimensions: 58 mm, Ø 8 mm, ½ inch thread
Enclosure rating: IP40
Thermostat Description (See Fig. 1)
1 – activation indicator LED
2 – display
3 – up arrow (increase value)
4 – down arrow (decrease value)
Installation
(See Fig. 2)
The thermowell is fitted with a 1/2" external thread, which is to be screwed into the coupling collar
fitted at the spot where you need to measure temperature (piping, tank). The thermostat's sensor is
inserted into the thermowell so that the body of the thermostat is in contact with the thermowell. It
is then secured in this position using the screw on the plastic collar.
Electrical Connection
1. Remove the 2 screws on the front housing of the thermostat.
2. Carefully remove the front housing.
3. Connect in accordance with the following diagram (see Fig. 2):
• Pump
• Power – 230 V
• Jump – jumper
• PE – protective earth, prevents injury by electric current
4. The thermostat features a screwless conductor connection. Press downwards onto the top plastic
connector with e.g. a screwdriver. The terminal contact will release. Plug in the conductor. Repeat
the process for all conductors needed for connection. Replace the screws.
Installation should be carried out by a qualified person!
Installation must always be performed when power is turned off; follow safety specifications. Main-
tain the maximum switched load listed in technical specifications! The manufacturer is not liable
for inexpert installation.
5 – on/off/function setting button
6 – screws
7 – thermowell locking screw
8 – thermowell
3

Publicidad

loading