4) Place the icemaker on the top of the Storage Bin. Be careful not to
damage the icemaker frame and the Bin Control Switch. See Fig. 5.
5) Secure the icemaker to the Storage Bin at the rear, by using the
mounting brackets and bolts provided. See Fig. 5.
Bolt
Mounting
Bolt
Bracket
Mounting
Bracket
6) Replace the icemaker panels in their correct position.
4. STACKING ICEMAKERS
WARNING
Check the icemaker models. A D-type icemaker and an X-type
icemaker will be required for stacking two icemakers. A D-type
icemaker and two X-type icemakers will be required when
stacking three icemakers. The D-type icemaker is designed
for the upper unit, and the X-type for the middle and lower
units. The D-type and X-type icemakers are provided with
two different types of Bin Control Switch. Use the Bin Control
Switch of the lower (and middle) X-type icemakers when
stacking icemakers. The Bin Control Switch must be removed
from the upper unit (Fig. 7). Misconnection or no connection
may cause serious damage to the icemaker units, resulting in
failure.
) Prepare and position the Storage Bin as detailed in ) and 2) in "3.
INSTALLATION".
2) Remove the icemaker panels. The Rear Panel is not required to
be removed for installation. See ". UNPACKING".
3) Attach the lower unit (X-type) on the top of the Storage Bin. See
Fig. 5.
4) Secure the lower unit (X-type) to the Storage Bin at the rear, by
using the mounting brackets and bolts provided. See Fig. 5.
5) Remove the shipping tape holding the Bin Control Switch on the
Drain Pan. Attach the Bin Control Switch to the frame located at
the left bottom of the condensing unit, and secure it using the two
screws and the two washers provided. See Fig. 6.
Bin Control Switch
Drain Pan
Screw
Washer
Icemaker
Bin
Fig. 5
Handle with care
Frame
Bin Control Switch
Fig. 6
6) Before stacking, remove the clear plastic cover on the upper or
middle unit wiring channel. Disconnect the Bin Control Switch
leads (with three-way plug). Remove the screws and the Bin
Control Switch. When stacking two or three icemakers, the switch
for the upper unit will not be required. Keep it after removal. See
Fig. 7.
Upper Unit
Remove Bin
Control Switch
7) Attach the upper or middle unit on the lower unit. See Fig. 8.
8) Secure the two units with the two bolts and the two nuts provided.
See Fig. 8.
9) Place the Ice Chute (lower or middle unit accessory) and secure it
to the Bracket with the two screws. See Fig. 8.
Upper Unit
Lower Unit
0) Connect the leads (with three-way plug) located in the lower unit
wiring channel to the upper unit receptacle, unplugged in the
above step 6). Secure the leads using the plastic clamp provided.
Place the plastic cover in position. See Fig. 9.
Upper Unit
Lower Unit
) Replace the icemaker panels in their correct position.
Note: If stacking three icemakers, repeat the instructions 6) - ) for
the upper unit. Remember, only ONE Bin Control is needed
regardless of configuration. The Bin Control extension leads
are pre-wired with the plug and will be found coiled in the X-type
wiring channel.
2
Screw
Disconnect leads
Fig. 7
Screw
Nut
Ice Chute
Bolt
Ice Chute
Bracket
Fig. 8
Receptacle
Wiring Channel
Plug
Plastic Clamp
Fig. 9