The permanent electrical installation must only be
wired by a professional electrician. We recom-
mend installing a residual-current circuit breaker
(RCCB) in the appliance's power supply circuit.
Do not kink or trap the connection cable, and
¡
keep it away from sharp edges.
Route the connection cable in such a way that it
¡
does not touch the hot casing.
Use only the connection cable that is supplied
¡
with the appliance or is provided by technical
after-sales service.
This appliance complies with the EC interference
¡
suppression regulations.
The appliance corresponds to protection class 1.
¡
You should therefore only use the appliance with
a protective earth connection.
The manufacturer shall assume no liability for mal-
¡
functions or damage resulting from incorrect elec-
trical wiring.
Preparing the electrical connection
Requirement: Only after-sales service staff who have
been trained accordingly may carry out work on the
inside of the appliance or replace the power cord.
Observe the information about the electrical con-
1.
nection.
An incorrect installation, an improper installation
or connection invalidates the warranty.
If a longer mains power cable is required, contact
2.
the after-sales service. Connecting cables up to
2.20 m are available.
On appliances without a preinstalled cable, insert
3.
the power cable into the mains socket.
Opening the mains socket
Use a screwdriver to lift the cover of the mains
outlet.
→ Fig.
16
Preparing the mains socket
Undo the screw.
1.
→ Fig.
17
Use a screwdriver to lift the strain relief.
2.
→ Fig.
18
Loosen the strain relief.
3.
→ Fig.
19
Connecting the cable to the mains socket
For 3 N, connect the cable to the mains socket in
1.
accordance with the following figure.
→ Fig.
20
For 2 N, connect the cable to the mains socket in
2.
accordance with the following figure.
→ Fig.
21
For 1 N, connect the cable to the mains socket in
3.
accordance with the following figure.
→ Fig.
22
For 2 L/2 N, connect the cable to the mains
4.
socket in accordance with the following figure.
→ Fig.
23
Note the colours of the cables.
5.
– BN: Brown
– BU: Blue
– GN/YE: Yellow and green
– BK: Black
– GY: Grey
If required, install the enclosed copper bridges in
6.
accordance with the connection diagram.
Connect the cables and then tighten the screws of
7.
the mains socket.
For a 1 N~ or 2 L/2 N connection in accordance
8.
with the connection diagram, 1 corresponds to the
fan motor.
For a 2 N~/3 N~ connection, phase L1 (grey) cor-
9.
responds to the fan motor.
Secure the cable in the mains socket
Use the strain relief to secure the power cable in
1.
place.
Tighten the screw at the correct position.
2.
Do not use a cordless screwdriver.
→ Fig.
24
To facilitate closing the mains socket, arrange the
3.
cables in the central area of the mains socket.
Close the cover on the mains socket.
4.
QR code: Electrical connection
This is where you will find the QR code for the video
for the electrical connection.
→ Fig.
25
Instructions for the exhaust air pipe
The appliance manufacturer does not provide any
warranty for faults attributable to the pipeline.
Use a short, straight exhaust air pipe with as large
¡
a pipe diameter as possible.
Long, rough exhaust air pipes, many pipe bends
¡
or small pipe diameters reduce the suction power
and increase the fan noise.
Use an exhaust air pipe that is made of non-com-
¡
bustible material.
To prevent condensate from returning, fit the ex-
¡
haust pipe with a 1° gradient from the appliance.
Instructions for the air extraction mode
For air extraction mode, a one-way flap should be in-
stalled.
Notes
If a one-way flap is not included with the appli-
¡
ance, one can be ordered from a specialist re-
tailer.
If the exhaust air is conveyed through the external
¡
wall, a telescopic duct should be used.
Checking the units
Check whether the fitted unit is level and has suffi-
1.
cient load-bearing capacity.
The maximum weight of the appliance is approx.
25 kg.
The worktop into which you are fitting the appli-
ance must be able to withstand loads of approx.
60 kg.
Ensure that the stability of the fitted unit is also
2.
guaranteed following cut-out work.
Use suitable substructures to ensure the load-
3.
bearing capacity and stability, particularly in the
case of thin worktops.
Take the appliance weight, including additional
load, into consideration.
Use heat-resistant and moisture-resistant rein-
forcement material.
Ensure that the fitted unit is heat-resistant up to
4.
90 °C.
Do not support any other appliances, e.g. ovens,
5.
refrigerators, dishwashers or washing machines.
Only check that the appliance is level once it has
6.
been installed in the installation opening.
You can freely select the clearance to a top cab-
7.
inet. In doing so, take into consideration the ease
of use and ergonomics when using the plate.