Errors
8
Error message in display
regarding pressure values
9
Inlet pressure is too low
10
Clogged pre-filter
11
High level of conductivity
is shown in display
-
Applies to all error types
7 Technical Data
Technology
Capacity
Membrane
Min./ Max. operating pressure
Max. outlet pressure
Water intake temperature
Ambiente temperature during
storage/transport
Max. conductivity of raw water
Flow rate at 25°C (at 15°)
Water conversion factor
EN
Power supply
Dimensions (W/D/H) of system
Dimensions (W/D/H) of pre-filter
Weight of system (dry)
Water inlet and outlet connections
Operating position
8
Root cause
Pressure values might have been exceeded
once or regularly.
Shut-off valve is not opened completely
Pressure is adjusted
Exceptionally high particle load in raw water
Stagnation effect after minutes of non-usage
Membrane exhausted
Water demand and filtrate production times
too short to realize constant salt retention
Root cause cannot be identified on site
Reverse osmosis, activated carbon filtration
Pre-Filter: 500,000 l
2 x 500 GPD (gallons per day)
1– 6 bar; Maximum inlet pressure: 8.6 bar
2.5 bar
4–35 °C
0–50 °C
<1500 µS/cm
200 l/h (140 l/h)
up to 50 %
220-240 V / 50 Hz / 250 W
14.5 / 41 / 43 cm
21 / 17 / 41 cm
16.2 kg
G 3/4"
Horizontal or vertical
Measures service technician
Restart the RO system and check, if inlet and
pump pressure are within specification. Adjust
pump pressure if necessary.
Fully open shut-off valve
Check pressure reducer, if it is still in specification.
Install a commercial sediment filter with an
adequate flowrate upfront.
View conductivity development during filtrate
production for minimum 1 minute, value should
decrease significantly. If not, membrane might be
exhausted
Exchange membranes
Install a storage tank from the accessory portfolio
to buffer filtrate and increase filtrate production
volumes.
Complaint process via your local BRITA
sales partner