Descargar Imprimir esta página

FEIDER Machines FG800 Manual Del Usuario página 33

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 11
Electrical safety
Before each use ensure that the load to be connected does not exceed the power of the current produced by
the generator.
To avoid electric shock, you must follow the following instructions:
Do not touch the generator with wet hands.
Do not run the generator under rain or snow.
Do not run the generator near water.
Connect the generator to earth. Use a sufficiently thick conductor for the earth wire.
Do not operate the generator in parallel with another generator.
If using electrical extensions, make sure that they are sufficiently thick to transport the current and that they are
used correctly.
The connection of a generator used for auxiliary power to the electrical installation of a building must be
performed by a qualified electrician, and in conformity to the provisions of the applicable laws and norms in the
field of electricity. Incorrect connections will cause leakage of the current from the generator into the lines of the
public electricity company. Such leakage could electrocute the workers of the public electricity company working
on the network or other persons in contact with the line during a power cut. Also, when the public power supply
is re-established, the generator can explode, catch fire or generate fires in the building's electrical installation.
Before connecting electrical devices to the generator, make sure that their voltage specifications and frequency
of functioning correspond to the technical characteristics of the generator. There may be damage if the device
connected is not designed to function with a voltage tolerance of +/- 10% or a frequency tolerance of +/- 3 %
compared with those of the generator.
Protection of the environment
You must periodically check the silencer (Before doing this, switch off the generator and let it cool completely). A
damaged silencer increases noise.
Do not throw motor oil into the drains but deposit it at a collection point set up for that purpose.
The fuel for this machine is combustible and explosive. After stopping the machine, you must handle the
remaining fuel correctly and meet local environmental requirements.
33

Publicidad

loading