– Install the side gas pipe grommet with
the control panel cable in the side hole.
Fig. 33
Checking for gas leaks
Risk of death and personal injury through
fire and/or explosion!
• DO NOT use matches, candles or other
sources of ignition when checking for gas
leaks.
• After the gas supply is connected, check
for gas leaks at all gas connections. Use a
gas leak detection liquid.
1. Turn OFF the electrical power supply
2.
Damage to the appliance from
test pressure higher than 60 in. wc
(150 mbar). Ensure that the test pres-
sure is lower than 60 in. wc (150 mbar).
3. Turn on the gas.
4. Check the appliance and all gas connections
for gas leaks with leak detection liquid.
– Bubbles indicate a gas leak that must be
repaired.
5. Repair gas leaks as needed.
6. Repeat check for gas leaks at all gas connec-
tions.
36
Control panel cable
Gas pipe
grommet
(side)
Functional check
1. Start the appliance (refer to "Starting the ap-
pliance" on page 9).
2. Check the appliance for proper functionality.
If faults occur during operation of the
appliance, refer to "Troubleshooting" on
page 22.
3. Provide operating and installation instruc-
tions to the vehicle owner.
The appliance is now ready for normal operation.