Operating instructions
Symbols used
The symbol indicates potential dangers.
Note containing information and tips.
The use of upright gas cylinders from which gas is extracted
in the gas phase is mandatory when operating the
MonoControl CS gas pressure regulation system. Gas cylinders
from which gas is extracted in the liquid phase (e.g. for fork
lifts) must not be used, since they would result in damage to
the gas system.
Start-up
Open gas remote switch if present.
1.
2.
3.
1. Open cylinder valve.
2. Firmly press the hose rupture protection (green button) on
the high pressure hose.
3. If necessary (e.g. after a new installation or inadvertently
striking the gas cylinder against the gas pressure regulation
system), press the green reset button (crash sensor trigger-
ing element reset) on the MonoControl CS.
Changing the LPG cylinder
Please use the included screwing tool to attach and remove the
high pressure hoses. It will help you generate the necessary
tightening torque and will prevent damage to the screw fit-
tings, which may otherwise result from using an improper tool.
Residual gas: Do not smoke, avoid open flames!
–
Close the empty gas cylinder's valve.
–
Remove the high pressure hose from the gas cylinder or
remove the slip-on adapter, if present.
–
Attach the high pressure hose to the full gas cylinder or fit
the slip-on adapter, if present.
–
Open the full cylinder's valve.
–
Press the hose rupture protection (see "Startup").
Anytime after making changes, check the hose connec-
tion to the cylinder valve for leaks (see "Checking for
leaks in the high-pressure section").
11