If gas system exhibits a leak, close the gas cylinder valve
and have the gas system repaired immediately by an expert;
do not open the gas cylinder valve until repair is complete.
When testing is complete, screw the threaded cap back
onto the test connection.
Maintenance
The MonoControl CS gas pressure regulation system is main-
tenance free.
In Germany, the gas system must be retested every 2 years by
a liquid gas specialist (DVFG, TÜV, DEKRA). The test must be
confirmed on the respective test certificate (G 607).
In countries where testing is not mandatory, we recommend
that the gas system is tested every 2 years for your own safety.
Pressure regulating devices and hoses must be replaced with
new ones no more than 10 years after their date of manufac-
ture (every 8 years if used commercially). This is the responsi-
bility of the operator.
Accessories
High-pressure hoses
(with hose rupture protection) see page 58
1.5-metre connection hose
for connecting external gas cylinders
– connection G.5 for Germany –
(part no. 50020-61300)
Replacement gasket
for high-pressure connection M20 x 1.5 (G.13)
(part no. 50020-76300)
DuoComfort
Changeover valve for two-cylinder system
– complies with requirements of BGV D 34 –
(part no. 51500-01)
EisEx regulator heating
(part no. 53101-01)
Angle union 90°
(part no. 50020-56000)
Extension kit
required when gas cylinders separated by more than 100 cm
(part no. 50020-61100)
Gas remote switch
for turning off the gas supply from inside the vehicle
GS 8
(part no. 57013-01)
GS 10
(part no. 57023-01)
13