Connection recommendation
3 phase (N3)
380-400 V mains three-phase connection with operating
•
neutral conductor.
-Bridge connects the terminals 4-5.
•
-Phase sequence according to 1-2-3.
•
-Neutral conductor on 4 and 5.
•
12.5 Installing the oven
Connect the oven to the mains power supply.
•
Slide the oven a little into the previously prepared
conversion cabinet and connect it to the hob.
Insert the compact plug into the connection opening, see
•
Fig. 9 Rear of the oven.
Slide the oven completely into the conversion cabinet.
•
Secure in this position with four screws at the points
shown in the sketch (Fig.12).
Final inspection
Set all switches on the cooker to "0"
•
Switch on the fuse for the cooker power circuit again
Set the clock on the timer
•
Switch on the cooking zones and oven and check the
•
function
12.6 Remove oven and glass ceramic hob
Electrocution hazard
→ Switch off or unscrew the fuse for
the cooker power circuit.
To remove the oven:
→ Loosen all 4 fixing screws (Fig. 12)
→ Lift the oven slightly and pull it out carefully.
Figure 10 3 phases N3
Figure 11 Oven
EN
Page | 51