Warning! Check the insulation on the cables
and plugs each time before use. If there are any
defects in the insulation, the equipment must not
be used.
Warning! Have repairs carried out only by an au-
thorized workshop or by the manufacturer.
Inserting and removing the battery
(Fig. 15a/15b)
Caution! Use the generator only with a mainte-
nance-free 12 V battery.
Tighten the holder (Fig. 15a). First connect the
red cable (+) and then the black cable (-) (Fig.
15b). Remove it in reverse order.
Caution! Do not disconnect the battery from the
electrical system during operation as this may
destroy the charge electronics.
Charging the battery from the electrical sys-
tem
The battery is charged by the generator via the
electrical system during operation.
Maintenance and care of the battery
Ensure that your battery is always fitted se-
curely.
A perfect connection to the cable network of
the electrical system must be ensured at all
times.
Keep the battery clean and dry.
6. Operation
Important! You must fi ll up with engine oil and
fuel before you can start the engine.
Check the fuel level and top it up if necessary
Make sure that the generator has sufficient
ventilation
Make sure that the ignition cable is secured to
the spark plug
Inspect the immediate vicinity of the gene-
rator
Disconnect any electrical equipment which
may already be connected to the generator
6.1.1 Starting up with the electric starter
Open the petrol cock (13) by turning it down
Set the ON/OFF switch (10) to the „ON" po-
sition
Anl_TC_PG_8000_SPK13.indb 23
Anl_TC_PG_8000_SPK13.indb 23
GB
Move the choke lever (11) to position I Ø I.
Start the engine by turning the ignition key in
the ignition lock (Fig. 1/Item 10). Once the en-
gine has started, turn the ignition key immedi-
ately back to its initial position. If you actuate
the ignition key again while the engine is run-
ning, you will damage the starting system.
Push the choke lever (11) back after the engi-
ne has started.
6.1.2 Starting up with the reversing starter
Open the petrol cock (13) by turning it down
Move the ON/OFF switch (10) to position
„ON" with the key.
Move the choke lever (11) to position IØI.
Start the engine with the reversing starter (12)
by pulling the handle forcefully. If the engine
does not start, pull the handle again.
Push the choke lever (11) back again after
the engine has started.
Important!
When starting with the reserve starter, the motor
may recoil suddenly as it starts up, resulting in
hand injuries. Wear protective gloves when star-
ting the equipment.
6.2 Connecting consumers to the generator
Set the selector switch (Fig. 3 / Item 27) to the
left to use the 230 V~ sockets.
Important: Even though the continuous power
(S1) of 3200 W is shared in this position bet-
ween the 2 sockets, it is possible to load only
one socket with 3200 W.
Set the selector switch (Fig. 3 / Item 27) to
the right to activate the 400 V 3~ socket. Im-
portant: This socket is allowed to be loaded
continuously (S1) with 3600 W and tempora-
rily for a maximum of 10 seconds with 8000
W (from standstill, with the generator cooled
down).
The generator is suitable for alternating volta-
ge appliances for 230 V~ and 400 V 3~.
Do not connect the generator to the
household mains system as this may result
in damage to the generator itself or to other
electrical appliances in your home.
Note: Some electrical appliances (power jigsaws,
drills, etc.) may have a higher level of power con-
sumption when used in diffi cult conditions.