FinishControl 4000 18V
15
CORRECTION OF MALFUNCTIONS
MALFUNCTION
The unit will not start
No coating material emerges
from the nozzle
Coating material drips from the
nozzle
Atomisation too coarse
Spray jet pulsates
Coating material causes "paint
tears
Excessive paint mist (overspray)
Paint in the ventilating hose
CAUSE
•
Battery flat, faulty or incompatible
•
Device overheated
•
Nozzle clogged
•
Material volume setting too low
•
Paint container seal damaged
•
No pressure build-up in container
•
Container empty
•
Ventilation hose loose/damaged
•
Feed tube loose
•
Feed tube / feed tube filter clogged
•
Air vent on feed tube blocked
•
Diaphragm stuck
•
Air cap, nozzle or needle soiled
•
Spray attachment incorrectly
assembled
•
Nozzle loose
•
Nozzle seal is missing or worn
•
Nozzle worn
•
Needle worn or damaged
•
Material volume too large
•
Nozzle contaminated
•
Viscosity of coating material too high
•
Too little pressure build-up in
container
•
Air filter heavily soiled
•
Amount of air too low
•
Air cap assembled incorrectly
•
Coating material in container running
out
•
Nozzle seal is missing or worn
•
Air filter heavily soiled
•
Feed tube loose
•
Feed tube / feed tube filter clogged
•
Too much coating material applied
•
Distance too small
•
Incorrect spray attachment
•
Distance to the object too large
•
Too much coating material applied
•
Amount of air too high
•
Coating substance over-diluted
•
Incorrect spray attachment
•
Diaphragm soiled
•
Diaphragm defective
CORRECTION OF MALFUNCTIONS
REMEDY
•
Battery flat, faulty or incompatible
•
Let the device cool down approx. 10 minutes,
check the air filter, do not cover the intake slots
•
Clean
•
Increase volume
•
Replace
•
Tighten container
•
Refill
•
Insert or replace
•
Insert
•
Clean or use another filter
•
Clean
•
Remove and clean (see section 14.2)
•
Clean
•
Assemble correctly (see section 13.1)
•
Tighten Union nut
•
Insert an intact nozzle seal
•
Change
•
Replace the needle (service set 2434518)
•
Reduce volume
•
Clean
•
Dilute further
•
Tighten container
•
Change (see section 14.1)
•
Increase volume
•
Snap air cap properly into place (fig. 16)
•
Refill
•
Insert an intact nozzle seal
•
Change (see section 14.1)
•
Insert
•
Clean or use another filter
•
Reduce volume
•
Increase distance
•
Use another spray attachment
•
Reduce distance
•
Reduce volume
•
Reduce volume
•
Reduce degree of dilution
•
Use another spray attachment
•
Clean the diaphragm (see section 14.2)
•
Replace the diaphragm (see section 14.2)
EN
23