Descargar Imprimir esta página

WAGNER FINISH CONTROL 4000 18V Manual De Instrucciones página 29

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 61
FinishControl 4000 18V
15
CORRECTION OF MALFUNCTIONS
MALFUNCTION
The unit will not start
No coating material emerges
from the nozzle
Coating material drips from the
nozzle
Atomisation too coarse
Spray jet pulsates
Coating material causes "paint
tears
Excessive paint mist (overspray)
Paint in the ventilating hose
CAUSE
Battery flat, faulty or incompatible
Device overheated
Nozzle clogged
Material volume setting too low
Paint container seal damaged
No pressure build-up in container
Container empty
Ventilation hose loose/damaged
Feed tube loose
Feed tube / feed tube filter clogged
Air vent on feed tube blocked
Diaphragm stuck
Air cap, nozzle or needle soiled
Spray attachment incorrectly
assembled
Nozzle loose
Nozzle seal is missing or worn
Nozzle worn
Needle worn or damaged
Material volume too large
Nozzle contaminated
Viscosity of coating material too high
Too little pressure build-up in
container
Air filter heavily soiled
Amount of air too low
Air cap assembled incorrectly
Coating material in container running
out
Nozzle seal is missing or worn
Air filter heavily soiled
Feed tube loose
Feed tube / feed tube filter clogged
Too much coating material applied
Distance too small
Incorrect spray attachment
Distance to the object too large
Too much coating material applied
Amount of air too high
Coating substance over-diluted
Incorrect spray attachment
Diaphragm soiled
Diaphragm defective
CORRECTION OF MALFUNCTIONS
REMEDY
Battery flat, faulty or incompatible
Let the device cool down approx. 10 minutes,
check the air filter, do not cover the intake slots
Clean
Increase volume
Replace
Tighten container
Refill
Insert or replace
Insert
Clean or use another filter
Clean
Remove and clean (see section 14.2)
Clean
Assemble correctly (see section 13.1)
Tighten Union nut
Insert an intact nozzle seal
Change
Replace the needle (service set 2434518)
Reduce volume
Clean
Dilute further
Tighten container
Change (see section 14.1)
Increase volume
Snap air cap properly into place (fig. 16)
Refill
Insert an intact nozzle seal
Change (see section 14.1)
Insert
Clean or use another filter
Reduce volume
Increase distance
Use another spray attachment
Reduce distance
Reduce volume
Reduce volume
Reduce degree of dilution
Use another spray attachment
Clean the diaphragm (see section 14.2)
Replace the diaphragm (see section 14.2)
EN
23

Publicidad

loading